Outdoor Unit CH3682

P.C.Board

Part No.

Controls

Circuit Fuse

Compressor

Control P.C.B

Noise Filer P.C.B

H.I.C.Board

CR-CH3682-F

POW-CH3082-B1

HIC-CH3072R-C1

Microprocessor

-

-

400V 3.5A

250V 25A

-

 

Type

 

 

DC Twin Rotary (Hermetic)

 

Compressor Model / Nominal Output

 

 

C-9RVN273H0H / 2,500W

 

Compressor Oil ... Amount

Pints (cc)

FV68S ... 2.98 (1,400)

 

Coil Resistance (Ambient Temp. 77 °F (25 °C)) Ohm

T - R : 0.169

 

 

 

 

 

T - S : 0.169

 

 

 

 

 

R - S : 0.169

 

Safety Device

 

 

Yes

 

 

CT (Peak current cut-off control)

 

 

Compressor Discharge Temp. Control

Yes

 

 

Operation cut-off control in abnormal ambient Temp.

Yes

 

 

Overload Relay

 

Model

CS-7L110

 

 

 

Operation Temp.

Open : 230 °F (110 °C), Close : 203 °F (95 °C)

 

Run Capacitor

 

Micro F

-

 

 

 

 

VAC

-

 

Crankcase Heater

 

 

230V 30W

Fan

Type

 

Q'ty ... Dia.

inch (mm)

Propeller

1 ... D19-9/32 (D490)

Fan Motor

 

 

 

Type

 

DC Motor

 

Model ... Q'ty

 

SIC-71FW-D8120-4A ... 1

 

No. of Poles

 

8

 

Rough Measure RPM (Cool / Heat)

 

750 / 750

 

Nominal Output

W

142

 

Coil Resistance

Ohm

-

 

(Ambient Temp. 68 °F (20 °C))

 

 

 

 

 

 

 

Safety Device

 

 

 

 

Type

 

Internal Controller

 

 

Over- Current Protection

 

Yes

 

 

Over- Heat Protection

 

Yes

 

Run Capacitor

Micro F

-

 

 

 

VAC

-

 

 

 

 

 

Heat Exchanger Coil

 

 

 

Coil

 

Aluminum Plate Fin / Copper Tube

 

Rows

 

2

 

Fins per inch

 

21.2

 

Face Area

ft2 (m2)

8.05 (0.748)

External Finish

Acrylic baked-on enamel finish

DATA SUBJECT TO CHANGE WITHOUT NOTICE.