Sanyo KHS3682 + CH3682, KHS3082 + CH3082 service manual CH3682 Voltage230V Cooling

Models: KHS3082 + CH3082 CH3682 CH3082 KHS3682 + CH3682

1 109
Download 109 pages 19.55 Kb
Page 32
Image 32

Indoor Unit

KHS3682

 

 

 

 

Outdoor Unit

CH3682

 

 

 

 

(1) Voltage:230V

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

< 230V >

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

Performance at

 

 

 

 

230V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.4

19.6

20.0

 

 

 

Power input

W

39

3,961

4,000

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

Performance at

 

 

 

 

230V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.5

17.7

18.2

 

 

 

Power input

W

43

3,607

3,650

Rating conditions:

Indoor air temperature

70°F (21.1°C) D.B.

 

 

 

 

Outdoor air temperature

47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.

 

(2) Voltage:208V

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

< 208V >

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

Performance at

 

 

 

 

208V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.4

21.5

21.9

 

 

 

Power input

W

39

3,961

4,000

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

Performance at

 

 

 

 

208V Single-phase 60Hz

 

Rating conditions

 

Running amp.

A

0.5

19.4

19.9

 

 

 

Power input

W

43

3,607

3,650

Rating conditions:

Indoor air temperature

70°F (21.1°C) D.B.

 

 

 

 

Outdoor air temperature

47°F (8.3°C) D.B. / 43°F (6.1°C) W.B.

 