2RECORD SET

z When only one camera is connected, recording is

performed at 25 FPS even if 50 FPS is set.

z Assuming that two or more cameras are connected and

“ALARM INTERLEAVE” is set to “ALL”, when 50 FPS is

16 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

“ALARM” appears in the operation display.

When an alarm occurs, the number of alarms is displayed.

set, the actual recording rate is roughly the recording rate

divided by the number of cameras. (Example: When four

cameras are connected and the recording rate setting is 50

FPS, the actual recording rate is 12.5 FPS.) It varies

depending on the setting of “ALARM INTERLEAVE” and

the number of alarms.

14 Turn the shuttle dial clockwise.

“20SEC” flashes.

EXIT/OSD

Number of alarms “ALARM” display

01-01-07 00:00:00 REC REPEAT EN A ALARM 0000001

02

<ALARM REC MODE

SET>

ALARM RECORDING

: ENABLED

PICTURE QUALITY

: ENHANCED

PICTURE QUALITY SET

->

AUDIO RECORDING

: ON

ALARM INTERLEAVE

: ONLY

REC RATE:A12.5FPS, DURATION: 20SEC

PRE-ALARM RECORDING

: ***

REC RATE: ***** FPS,

DURATION: *****

ALARM TRIGGER

: ALARM

MOTION SENSOR

->

15 Turn the jog dial to select the “DURATION” setting and then turn the shuttle dial clockwise.

The cursor moves to “PRE-ALARM RECORDING”.

 

 

<ALARM REC MODE SET>

 

 

ALARM RECORDING

: ENABLED

 

 

PICTURE QUALITY

: ENHANCED

 

 

PICTURE QUALITY SET

->

 

 

 

AUDIO RECORDING

: ON

 

 

ALARM INTERLEAVE

: ONLY

 

 

REC RATE:A12.5FPS, DURATION: 20SEC

 

 

PRE-ALARM RECORDING

: OFF

 

 

 

REC RATE: ***** FPS,

DURATION: *****

 

 

ALARM TRIGGER

: ALARM

 

 

MOTION SENSOR

->

 

[Settings] (‹ indicates default setting)

 

 

 

 

 

 

Setting

 

Description

5SEC, 10SEC, ‹20SEC,

Records for the set duration for

40SEC, 1MIN, 2MIN, 3MIN,

each alarm.

 

 

4MIN, 5MIN, 10MIN, 15MIN

 

 

 

 

 

 

Records while an alarm is activated.

CCRecording continues for five seconds even if entry is less than five seconds.

zWhen an additional alarm is received on another channel while alarm recording is in progress, the number of alarms is incremented, i.e.they are counted as two alarms.

However, when an additional alarm is received on the same channel, both alarms are treated as one (e.g. an additional alarm is received on CH1 while the channel is being used for alarm recording.)

English

101