1INITIAL SET

Timer period operations settings

Example 2: Setting time period operation as follows. Automatic selection and monitor masking for “TIME PERIOD A”. (default setting)

Motion sensing for “TIME PERIOD B”.

9 Turn the jog dial to select “MOTION SENSOR” within “SELECT TIME PERIOD” and then turn the shuttle dial clockwise.

“TIME PERIOD A” flashes.

<TIME PERIOD SET>

 

 

TIME PERIOD

T-1

T-2

T-3

T-4

TIME PERIOD A

06:00

11:30

13:30

18:00

TIME PERIOD B

06:00

08:00

14:30

20:00

SELECT TIME PERIOD

 

 

 

SEQUENCE

 

TIME PERIOD A

MASK

 

TIME PERIOD A

MOTION SENSOR

TIME PERIOD A

10 Turn the jog dial to select “TIME PERIOD B” and then turn the shuttle dial clockwise.

The cursor moves to “TIME PERIOD A”.

 

<TIME PERIOD SET>

 

 

TIME PERIOD

T-1

T-2

T-3

T-4

 

 

 

 

 

 

 

TIME PERIOD A

06:00

11:30

13:30

18:00

 

TIME PERIOD B

06:00

08:00

14:30

20:00

SELECT TIME PERIOD

 

 

 

 

SEQUENCE

 

TIME PERIOD A

 

MASK

 

TIME PERIOD A

 

MOTION SENSOR

TIME PERIOD B

[Settings] (‹ indicates default setting)

SettingDescription

‹TIME PERIOD A Applies the setting of “TIME PERIOD A”

TIME PERIOD B Applies the setting of “TIME PERIOD B”

Applies the same setting for a whole day, rather than different settings for different times.

ALL DAY LONG z SEQUENCE, MASK:

Fixed to “T1 (00:00 - 24:00)”.

zMOTION SENSOR: Depends on the setting of “T1”.

11 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

EXIT/OSD

zAutomatic selection, masking, and motion sensors are all set to “TIME PERIOD A” by default setting.

zFor the above settings, “SEQUENCE” indicates automatic screen selection period and monitor settings (JP.134), “MASK” indicates mask settings (JP.136), and “MOTION SENSOR” indicates motion sensor settings (JP.105).

English