3RECORD SET

Setting audio recording

Audio can be recorded together with images during alarm recording. Note, however, that since this audio data is also stored in the recording area, the recording time for this area decreases.

6 Set “AUDIO RECORDING”.

[Settings] (‹ indicates default setting)

 

Setting

Description

‹OFF

Audio is not recorded.

 

ON

Audio is recorded.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zThe settings for audio recording are restricted by the settings for “ALARM INTERLEAVE (Step 7)” as follows: ONLY/SW/ALL:

Audio recording is enabled when “REC RATE (Step 8)” isset to 1 FPS or more. ALL (P-1 4):Audio recording is enabled when “REC RATE” for any oneof the program-registered cameras is set to 1 FPS or more. ONLY (P-1 4):

Audio recording is disabled.

zIf audio recording is unavailable due to restrictions, “AUDIORECORDING” will be forcibly switched to “OFF” when you click the [SAVE] button even if it is set to “ON”.

Setting the alarm interleave7 Set “ALARM INTERLEAVE” to the desired recording pattern.

[Settings] (‹ indicates default setting)

Setting

Description

‹ONLY

Video is recorded only from cameras with an

alarm occurring.

 

 

 

 

Recording is switched between video from a

SW

camera for which an alarm has occurred and

 

video from all connected cameras.

 

 

 

For all the connected cameras, video recording

ALL

starts at the same time when any one of the

 

cameras receives an alarm.

<“ONLY” program mode>

When a connected camera registered in the ONLY (P-1) program recording setting receives an alarm, ONLY (P-2) video recording starts at a recording rate ONLY (P-3) specified in the program.

ONLY (P-4) z Specify the program you want to apply from “P-1” to “P-4”.

zAudio recording is not available.

<“ALL” program mode>

When any one of the connected cameras registered in the program recording setting receives an alarm, video recording starts for all

ALL (P-1) the connected cameras at a recording rate ALL (P-2) which was independently specified for each ALL (P-3) connected camera in the program.

ALL (P-4) z Specify a program you want to apply from “P- 1 to P-4”.

zAudio recording is available only when any one of the cameras has a recording rate of 1 FPS or more.

zIn the program mode, there is a time lag of approximately up to one second between the alarm occurrence and start of recording, depending on the setting values of the recording rate.

8 Set “REC RATE” to the desired recording rate.

[Settings] (‹ indicates default setting)

 

 

Setting

Description

 

 

 

 

 

A50, A25, A16.67, ‹A12.5,

 

A8.333, A6.25, A5, A4.167,

Recording is performed at the

A3.571, A3.125, A2.778,

selected recording rate (unit:

A2.5, A2.273, A1.923,
FPS). (Audio can be recorded.)
A1.667, A1.471, A1.316,

 

A1.19, A1.087, A1

 

 

 

 

 

 

0.5, 0.333, 0.25, 0.2, 0.1,

Recording is performed at the

selected recording rate (unit:

0.05, 0.033

 

 

FPS). (Audio cannot be recorded.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zThe letter “A” is displayed in front of recording rates that can be set for audio recording.

zIf “ALARM INTERLEAVE (step 7)” is set to program mode, you cannot select the recording rate.

“***FPS” is automatically displayed when you click the [SAVE] button.

zWhen only one camera is connected, recording is performed at 25 FPS even if 50 FPS is set.

zWhen two or more cameras are connected and 50 FPS is set, the actual recording rate is roughly the recording rate divided by the number of cameras. (Example: When 4 cameras are connected and the recording rate setting is 50 FPS, the actual recording rate is 12.5 FPS)

9 Set “DURATION” to the desired alarm recording duration.

[Settings] (‹ indicates default setting)

Setting

Description

5SEC, 10SEC, ‹20SEC,

Records for the set duration for

40SEC, 1MIN, 2MIN, 3MIN,

each alarm.

4MIN, 5MIN, 10MIN, 15MIN

 

 

 

 

Records while an alarm is

CC

activated (Recording continues

for five seconds even if less than

 

 

five seconds).

 

 

English

193