9ADVANCED MENU SET

2. CAMERA CONTROL SET

Set when cameras with remote operation capability are connected.

Perform the following connections and set camera control to use in full screen display.

Connections necessary for remote operation:

zConnect coaxial control cameras to the VIDEO terminal.

zConnect the Sanyo RS-485 control camera to the RS-485 terminal (RJ-11).

zConnect the other companies’ RS485/422 control camera to the 2ND RS485/422 terminal.

1 Click the button on the operation panel.

The “MAIN MENU” is displayed.

2 Click “8. ADVANCED MENU SET”.

The “ADVANCED MENU SET” screen is displayed.

3 Click “2. CAMERA CONTROL SET”.

The “CAMERA CONTROL SET” screen is displayed. The DSR-5709P displays only nine channels.

6

5 4

8

10

9

4 Set “PROTOCOL” to the protocol corresponding to the dome camera.

[Settings] (‹ indicates default setting)

Setting

Description

‹OFF

No protocol

 

 

SANYO RS-485

SANYO RS-485

 

 

BBV COAX

BBV COAX

(Also supports AUX commands.)

 

 

 

PELCO COAX

PELCO COAX

 

 

2ND RS-485/422

2ND RS-485/422

 

 

COAX (H-SSP)

COAX (H-SSP)

 

 

5 The address (000 to 127) is displayed in “ADD”.

When “SANYO RS-485” or “2ND RS-485/422” is specified as the protocol, the address is displayed automatically.

6 In “ACTION”, specify the interlocking operation of the camera when an alarm is detected.

You can configure the camera to automatically change lens orientation, auto-pan or tour on alarm detection.

[Settings] (‹ indicates default setting)

 

Setting

Description

 

‹OFF

No action triggered.

 

 

 

 

 

 

 

 

 

 

 

Moves the camera lens to the angle

 

 

PRESET

corresponding to your selected preset

 

 

 

 

 

number.

 

 

 

 

 

 

PAN

Starts automatic panning.

 

 

 

 

 

 

TOUR

Starts tour.

 

 

 

 

 

 

SEQUENCE

Starts sequence.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zFor “PRESET”, you can set “PRESET2-9” with DSR-5709P and “PRESET2-16” with DSR-5716P.

zActually available actions depend on each camera. For more information, refer to the camera's instruction manual.

7 Use the same procedure to set the other channels.8 Set “2ND RS-485/422 PROTOCOL”.

[Settings] (‹ indicates default setting)

‹OFF, BBV, KALATEL, PELCO, SENSORMATIC

9 Set “DATA SPEED”.

[Settings] (‹ indicates default setting) ‹9600bps, 4800bps, 2400bps

10 Click [SAVE].

The setting is saved.

English

209