2RECORD SET

Setting sensitivity levels

13 Turn the shuttle dial clockwise.

“OFF” flashes.

A

CH01 T-1 LEVEL : OFF MODE : A

14 Turn the jog dial to select “OFF” or a sensitivity level between “1” to “10” and then turn the shuttle dial clockwise.

The cursor moves to “MODE”.

A

 

CH01 T-1 LEVEL : OFF

MODE : A

 

[Settings] (‹ indicates default setting)

 

 

 

 

Setting

Description

‹OFF

Motion sensing is disabled.

 

 

 

 

1 to 10

Motion sensing is enabled. Lower numbers
correspond to higher levels of sensitivity.

 

 

 

 

 

Setting sensor modes

15 Turn the shuttle dial clockwise.

“A” flashes.

A

CH01 T-1 LEVEL : OFF MODE : A

16 Turn the jog dial to select the “MODE” setting and then turn the shuttle dial clockwise.

The cursor moves to the top left sensor.

A

 

CH01 T-1 LEVEL : OFF MODE : A

[Settings] (‹ indicates default setting)

 

 

Setting

Description

‹A

The motion sensor alarm is triggered when a
moving object is detected in A.

 

BThe motion sensor alarm is triggered when a moving object is detected in B.

The motion sensor alarm is triggered when a A AND B moving object is detected by a sensor in both A

and B.

By setting A to important points (moving objects) and B to non-moving points, the motion sensor

A AND NB alarm is not triggered when the overall screen brightness changes. The motion sensor alarm only activates when A experiences a change and B does not.

The motion sensor alarm is triggered when anA TO B object is detected moving from A to B. (within 2 seconds from A to B)

The motion sensor alarm is triggered when an

B TO A object is detected moving from B to A. (within 2 seconds from B to A)17 Use the same procedure to set “LEVEL” and “MODE” for “T-2” through “T-4”.

zMotion sensor positions are common for “T-1” through “T- 4” and different settings cannot be made.

18 Turn the shuttle dial counter-clockwise.

Motion sensor settings are confirmed and the <ALARM REC MODE SET> screen is displayed once again.

English

107