8ADVANCED MENU SET

Camera control settings

Settings are required when a remote control camera(s) is connected with the digital video recorder.

Through making the connections by following the procedure below, you can control a camera(s) in the full screen mode.

Connections necessary for remote operation:

zConnect coaxial control cameras to the VIDEO terminal.

zConnect the Sanyo RS-485 control camera to the RS-485 (RJ-11) terminal.

zConnect another maker’s RS485/422 control camera to the 2ND RS485/422 terminal.

zIf “ADDRESS” in the <RS-485 SET> screen (JP.121) is set to between “001” and “008”, camera control settings can be performed. Camera control settings are not available if “ADDRESS” is set to “000” or between “009” and “127”.

zBefore configuring trigger actions, be sure to configure the settings under “ALARM REC MODE SET” and

“PROTOCOL/ADDRESS SET”.

1 Press the [MENU] button.

The MENU indicator lights up and the <MAIN MENU> is displayed.

MENU

2 Turn the jog dial to select “8.ADVANCED MENU SET” and then turn the shuttle dial clockwise.

The <ADVANCED MENU SET> screen is displayed.

3 Turn the jog dial to select “3.CAMERACONTROL SET” and then turn the shuttle dial clockwise.

The <CAMERA CONTROL SET> screen is displayed.

 

<CAMERA CONTROL SET>

 

 

 

 

1.

PROTOCOL/ADDRESS SET

->

2.

ALARM REC TRIGGER SET

->

4 Turn the jog dial to select “1.PROTOCOL/ADDRESS SET” and then turn the shuttle dial clockwise.

The <PROTOCOL/ADDRESS SET> screen is displayed.

 

 

<PROTOCOL/ADDRESS SET>

 

CH PROTOCOL

ADD.

 

CH PROTOCOL

ADD.

 

01

OFF

---

 

09

OFF

---

02

OFF

---

 

10

OFF

---

03

OFF

---

 

11

OFF

---

04

OFF

---

 

12

OFF

---

05

OFF

---

 

13

OFF

---

06

OFF

---

 

14

OFF

---

07

OFF

---

 

15

OFF

---

08

OFF

---

 

16

OFF

---

2ND RS-485/422 PROTOCOL : OFF

9600bps

5 Turn the jog dial to select the camera number corresponding to a connected dome camera and then turn the shuttle dial clockwise.

“OFF” flashes for “PROTOCOL”.

On the DSR-5709P, cameras No. 01-09 are displayed.

 

 

<PROTOCOL/ADDRESS SET>

 

 

 

ADD.

 

CH PROTOCOL

ADD.

 

 

 

01

OFF

---

 

09

OFF

---

 

OFF

---

 

10

OFF

---

03

OFF

---

 

11

OFF

---

04

OFF

---

 

12

OFF

---

05

OFF

---

 

13

OFF

---

06

OFF

---

 

14

OFF

---

07

OFF

---

 

15

OFF

---

08

OFF

---

 

16

OFF

---

2ND RS-485/422 PROTOCOL : OFF

9600bps

6 Turn the jog dial to select a protocol and then turn the shuttle dial clockwise.

The cursor moves to the next camera number.

 

<PROTOCOL/ADDRESS SET>

 

CH PROTOCOL

ADD.

 

CH PROTOCOL

ADD.

 

01

SANYO RS-485

001

 

09

OFF

---

02

OFF

---

 

10

OFF

---

03

OFF

---

 

11

OFF

---

04

OFF

---

 

12

OFF

---

05

OFF

---

 

13

OFF

---

06

OFF

---

 

14

OFF

---

07

OFF

---

 

15

OFF

---

08

OFF

---

 

16

OFF

---

 

2ND RS-485/422 PROTOCOL : OFF

9600bps

[Settings] (‹ indicates default setting)

 

 

 

 

Setting

Description

 

‹OFF

No protocol

 

SANYO RS485

SANYO RS485

 

BBV COAX

BBV COAX

 

(Also supports AUX commands.)

 

 

 

PELCO COAX

PELCO COAX

 

2ND RS-485/422

2ND RS-485/422

 

COAX (H-SSP)

COAX (H-SSP)

 

SETTINGS

150