3RECORD SET

Setting pre-alarm recording.

Use the following procedure to set the recording conditions to be used for pre-alarm. (JP.168)

10 Set “PRE-ALARM RECORDING” to “ON” or “OFF”.

[Settings] (‹ indicates default setting)

 

Setting

Description

 

 

 

 

‹OFF

Pre-alarm recording is disabled.

 

 

 

 

 

ON

Pre-alarm recording is enabled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zIf “ALARM RECORDING” is set to “OFF”, the PRE-ALARM RECORDING setting is displayed as “**” and cannot be set.

11 Set “REC RATE” to the desired recording rate.

[Settings] (‹ indicates default setting)

Setting

Description

 

 

A100, A50, A25, A16.67,

 

‹A12.5, A8.333, A6.25,

 

A5, A4.167, A3.571,

Recording is performed at the

A3.125, A2.778, A2.5,

selected recording rate (unit:

A2.273, A1.923, A1.667,

FPS).

A1.471, A1.316, A1.19,

 

A1.087, A1

 

 

 

The letter “A” is displayed in front of recording rates that can be set for audio recording.

zWhen mirroring is set to "ON", configurable recording rates are limited.

zWhen only one camera is connected, recording is performed at 25 FPS even if 50 or 100 FPS are set.

zWhen two or more cameras are connected and 50 or 100 FPS is set, the actual recording rate is roughly the recording rate divided by the number of cameras. (Example: When 8 cameras are connected and the recording rate setting is 100 FPS, the actual recording rate is 12.5 FPS)

12 Set “DURATION” to the desired pre- alarm recording duration.

[Settings] (‹ indicates default setting)

SettingDescription

5SEC, 10SEC, 20SEC,

40SEC, ‹1MIN, 2MIN, Records for the set duration. 3MIN, 4MIN, 5MIN, 10MIN,

15MIN

Setting alarm triggers

Use the following procedure to set the alarm triggers (i.e., launch signals), which function as operation conditions for alarm recording.

13 Set “ALARM TRIGGER” to the desiredlaunch signal for alarm recording.

[Settings] (‹ indicates default setting)

 

Setting

Description

‹ALARM

Starts recording when an external alarm is

activated.

 

 

 

 

 

 

 

 

 

 

SENSOR

Starts recording when a motion sensor is

 

activated.

 

 

 

 

 

 

 

 

 

 

ALARM AND

Starts recording when both an external alarm

 

SENSOR

and a motion sensor are activated

 

simultaneously.

 

 

 

 

 

 

 

 

 

 

ALARM OR

Starts recording when an external alarm or a

 

motion sensor is activated independent of the

 

SENSOR

 

other.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zExternal alarm detection:

This is used to describe input of an external detection signal from a door switch or the like to the unit’s ALARM IN terminal.

zMotion sensor detection:

This refers to detection of motion on the monitor in accordance with motion sensor settings.

zThe motion sensor settings are made on the digital video recorder.

14 Click [SAVE].

The setting is saved.

NETWORK

SETTINGS

194

English