2RECORD SET

zAfter an alarm duration has ended, the display returns to the screen prior to the alarm.

z“ALARM PRIORITY” cannot be selected when “MAIN MON. DISPLAY” is set to “9”, “16” or “NC”.

10 Turn the shuttle dial clockwise.

“NC” flashes.

<ALARM OPERATION SET>

ALARM RETRIGGER

: ON

MAIN MON. DISPLAY

: FULL

ALARM PRIORITY

: LAST

MON.2 DISPLAY

: NC

11 Turn the jog dial to select the “MON.2 DISPLAY” value and then turn the shuttle dial clockwise.

<ALARM OPERATION SET>

ALARM RETRIGGER

: ON

MAIN MON. DISPLAY

: FULL

ALARM PRIORITY

: LAST

MON.2 DISPLAY

: NC

[Settings] (‹ indicates default setting)

Setting

Description

‹NC

When an alarm is detected, Monitor 2 does

not change.

 

 

 

 

When a number of alarms occur, the

SWITCH

display switches between the video from

the corresponding cameras, showing each

 

 

for one second.

 

 

 

When a number of alarms occur, the most

LAST

recent alarm video is given priority and is

 

displayed.

 

 

 

When a number of alarms occur, only the

 

video for the first alarm is displayed.

FIRST

However, if the duration for the first alarm

 

expires, video for the next alarm is

 

displayed.

 

 

12 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

EXIT/OSD

Canceling an alarm

To forcibly cancel an alarm during alarm operation, press the [CAMERA SELECT] button for the camera with the alarm and hold it for approximately 3 seconds. Alternatively, connect a switch between the ALARM RESET terminal and C terminal (the grounded terminal), and turn on the switch to cancel an alarm that occurs.

ALARM

RESET

C

SETTINGS

110

English