8ADVANCED MENU SET

11 Turn the jog dial to select “2. ALARM REC TRIGGER SET” and then turn the shuttle dial clockwise.

The <ALAMR TRIGGER SET> screen is displayed.

 

 

<ALARM REC TRIGGER SET>

CH ACTION

 

 

CH ACTION

 

 

01

OFF

 

 

09 ---------

02

OFF

 

10 ---------

03

OFF

 

11 ---------

04

OFF

 

12 ---------

05

---------

13 ---------

06

---------

14 ---------

07

---------

15 ---------

08

---------

16 ---------

On the <ALARM REC TRIGGER SET> screen, you can specify the interlocked operation of the camera when an alarm is detected. You can configure the camera to automatically change lens orientation, auto-pan or tour on alarm detection.

12 Turn the jog dial to select a camera number, and then turn the shuttle dial clockwise.

“OFF” for “ACTION” flashes.

For DSR-5709P, the camera numbers from “01” to “09” are displayed.

 

 

<ALARM REC TRIGGER SET>

CH ACTION

 

CH ACTION

 

01

OFF

 

09 ---------

02

OFF

 

10 ---------

03

OFF

 

11 ---------

04

OFF

 

12 ---------

05

---------

13 ---------

06

---------

14 ---------

07

---------

15 ---------

08

---------

16 ---------

zIf a protocol is not set in the <PROTOCOL/ADDRESS SET> screen, “------” is displayed for “ACTION” and no value can be set.

13 Turn the jog dial to select the interlocked operation, and then turn the shuttle dial clockwise.

The cursor moves to the next “ACTION” field.

 

 

<ALARM REC TRIGGER SET>

CH ACTION

 

 

CH ACTION

 

 

01

OFF

 

09 ---------

 

 

 

 

02

OFF

 

 

10 ---------

03

OFF

 

11 ---------

04

OFF

 

12 ---------

05

---------

13 ---------

06

---------

14 ---------

07

---------

15 ---------

08

---------

16 ---------

[Settings] (‹ indicates default setting)

 

 

Setting

Description

‹OFF

No action triggered.

 

 

 

 

 

 

 

 

 

Moves the camera lens to the angle

 

PRESET

corresponding to your selected preset

 

 

 

 

number.

 

 

 

 

PAN

Starts automatic panning.

 

 

 

 

TOUR

Starts tour.

 

 

 

 

SEQUENCE

Starts sequence.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

zFor “PRESET”, you can set “PRESET2-9” with DSR-5709P and “PRESET2-16” with DSR-5716P.

zIn the case more than one camera has issued an alarm simultaneously, some or all trigger actions may fail to operate correctly because only one camera can be operated at a time.

zActually available actions depend on each camera. For more information, refer to the camera's instruction manual.

14 Use the same procedure as above to set the interlocked operation of other cameras.

15 Press the [EXIT/OSD] button.

The setting is completed and the display returns to the normal screen.

EXIT/OSD

SETTINGS

152

English