CX208/212 Programming Guide

Enable Options

Command Structure

<ESC>CLa

 

 

a

=

0

Disable Dispenser Option

 

 

 

1

Enable Dispenser option

 

<ESC>CKa

 

 

a

=

0

Disable Cutter Option

 

 

 

1

Enable cutter option

 

Example:

 

<ESC>CL1

 

Placement:

This command should be sendt in a separate data

 

stream.

 

 

 

Default:

 

<ESC>CL0 (Dispenser Disabled)

 

 

 

 

<ESC>CK0 (Cutter Disabled)

Command Function

To select the top-of-label sensing method.

Input to Printer

<ESC>AZLI2

 

 

Printer Output

Theres is no printer output as a result of this command.

Special Notes

1. The appropriate option must be installed before these commands

 

 

are effective.

2. Operation of the Dispenser and Cutter are dependent upon both the <ESC>Q Quantity, the <ESC>CB Backfeed and the <ESC>NULL (or <ESC>~) Cut commands.

Page 99

PN 9001092 Rev. A

SATO CX208/212 Printers

Page 103
Image 103
SATO CX208/212 manual Enable Options, ESC CL1