CX208/212 Programming Guide

Calibrate Sensor

Command Structure

<ESC>CA

 

 

Example:

<ESC>CA

 

Placement:

This command should be sent after the sensor type

 

 

has been selected with the <ESC>CI command. It

 

should

 

 

 

not be included with print job commands.

 

Default:

There is no default for this command.

Command Function

To adjust the label sensor for unique media and ribbon combinations.

Input to Printer

<ESC>AI2CZA

 

Printer Output

There is no printer output for this command. It will cause the printer to

 

feed a label while the characteristics of the label backing or eye-mark

 

are measured.

Special Notes

1.

The sensor is calibrated for the currently selected sensor type

 

 

(Eye-Mark or Transmissive).

 

2.

If the Sensor is disabled with a <ESC>CI0 command, no

 

 

calibration is performed.

 

3.

The sensor must be recalibrated whenever the sensor type is

 

 

changed.

 

4.

When calibrating the sensor for the CX200/212TT Thermal

 

 

Transfer unit operating in the thermal transfer mode, the ribbon

 

 

must be installed in the printer.