Unit 4: Printer Configuration

 

 

 

 

 

 

 

 

 

PGL EMULATION MODE (TABLE 4-10)

 

 

 

 

 

 

MENU

 

DESCRIPTION

 

 

 

 

 

 

 

Allows selection of whether the printer will ignore unformatted text. Example: With a simple text

 

 

 

field using a recognizable printer, the printer can either print this unformatted text or ignore it.

 

 

 

 

 

 

Ignore Text

 

Disable - factory default. Text in normal mode will be printed. Attributes to be printed depend

 

Disable*

 

 

 

 

on the PGL Normal menu setting.

 

 

 

 

 

 

 

Enable - any line of text (non-PGL commands) in normal mode will be ignored.

 

 

 

 

 

 

 

Allows setting the IGP/PGL feature so that it is enabled or disabled when the printer is powered

 

 

 

on.

 

 

Power on IGP/PGL

 

Enable - factory default. The IGP/PGL is enabled when the printer is powered on. The PGL

 

Enable*

 

 

feature is initialized in the Normal mode.

 

 

 

Disable - PGL is disabled when the printer is powered on. The PGL feature is initialized to

 

 

 

 

 

 

 

the Quite mode.

 

 

 

 

 

 

 

Ext Execute copy

 

 

 

Disable - factory default. Dynamic data, overlay data, etc., are not allowed if the optional

 

 

 

 

Form Count parameter (number of forms printed) is specified as part of the Execute

 

 

 

 

command. This setting is IGP-100 compatible.

 

Ext Execute Copy

 

 

 

 

 

 

 

Disable*

 

Enable - dynamic data, overlay data, etc., are allowed within a form where the Form Count

 

 

 

 

parameter is specified in the Execute command. In this case, the same form is printed for

 

 

 

 

 

 

 

 

whatever is the Form Count. Incremental data is not incremented since the printing page is

 

 

 

 

the same. The overlay data is only printed with the first form and not on subsequent forms,

 

 

 

 

and each form is printed on a separate page.

 

 

 

 

 

 

 

This option is designated for EAN/UCC-128 barcodes whose application idenitfier (AI) is 00.

 

 

 

Disable - factory default. The printable data field is printed with the AI enclosed in

 

 

 

 

AI 00 Spaces

 

 

 

 

parenthesis.

 

Disable*

 

 

 

 

Enable - the printable data field is printed with the UCC fields separated by spaces. This

 

 

 

 

 

 

 

option is IGP-X00 compatible.

 

 

 

 

 

 

 

Select Shift Out Character. Allows to specify a decimal code from 0 throgh 255 to be used in

 

 

 

place of Shift Out as the control code which allows access for the alternate set of control function

 

 

 

 

Select SO Char

 

 

 

characters.

 

14*

 

 

 

The allowable range is 0 to 255, and the default is 14.

 

 

 

 

 

 

 

 

 

 

 

 

 

This parameter instructs the IGP to ignore the character selected under the Select Character

 

 

 

menu.

 

 

 

 

Ignore Mode

 

 

 

Disable - factory default. The IGP does not ignore any characters.

 

Disable*

 

 

 

Enable - the IGP ignores the character specified in the Select Character menu.

 

 

 

 

 

 

 

 

 

 

 

 

 

Select Character. This parameter selects which character to discard when Ignore mode is

 

 

 

enabled.

 

 

 

 

Select Char

 

 

 

The allowable range is 0 to 255 (in decimal), and the default is 0.

 

0*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Determines whether the printer, with media already set at the top-of-form position, will advance

 

 

 

media to the next top-of-form position upon receipt of an FF command.

 

 

 

Enable - factory default. The printer will advance media from the presnt top-of-form position

 

Do FF at TOF

 

 

Enable*

 

 

to the next top-of-form position upon receipt of an FF command.

 

 

 

Disable - The printer will not advance media form the present top-of-form position to the next

 

 

 

 

 

 

 

top-of-form position upon receipt of an FF command.

 

 

 

 

 

GL408-412e Operator Manual

4-66

PN: 9001163A

Page 102
Image 102
SATO GL408/412E On the PGL Normal menu setting, Feature is initialized in the Normal mode, Quite mode, Ext Execute copy