Unit 4: Printer Configuration

 

 

 

 

 

 

 

 

 

IGL EMULATION MODE (TABLE 4-14)

 

 

 

 

 

 

MENU

 

DESCRIPTION

 

 

 

 

 

 

 

Select whether the data sent to the printer is translated as standard ASCII or EBCDIC. Many IBM

 

 

 

Mini/Main-Frame computers use EBCDIC which does not directly translate to ASCII.

 

 

 

 

IBM Translation

 

 

 

Disable - factory default. The IBM version of the selected character will not be used.

 

Disable*

 

 

 

Enable - the IBM version of the selected character set will be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

This menu determines if a zero numeral character wil be printed with a diagonal slash overlayed.

 

 

 

Font Based - factory default. Zero characters will print with a slash if the selected font type

 

 

 

 

designates that it has one. This mimics IPL3 printers where not all fonts contain a slashed

 

Slash Zero

 

 

 

Font Based*

 

 

zero.

 

 

 

Disable - factory default. Zero characters are never printed with a slash.

 

 

 

 

 

 

Enable - all zero characters will be printed with a slash, independent of the selected font.

 

 

 

This menu defines the code page position that contains the the Euro symbol.

 

 

The factory default is 0x0.

 

 

 

 

EURO Symbol

 

 

0x0*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Select whether the data is to be processed as it is received or if the printer is to wait until the

 

 

 

entire job has been sent prior to any commands being processed. This menu determines if the

 

 

 

data preparser will be active or inactive.

 

 

 

 

 

 

Preparsing data

 

Enable - factory default. The data received from the host is preprocessed to quickly respond

 

Disable*

 

 

 

 

to the immediate commands.

 

 

 

 

 

 

 

Disable - the data is processed synchronously; the commands are not processed until all

 

 

 

 

preceding commands have been processed.

 

 

 

 

 

 

 

This menu determines if a printer status message will be returned to the host on receipt of the

 

 

 

block terminator <ETX>. This is implemented only for serial interface, X-On/X-Off, or Intermec

 

 

 

protocol.

 

Status on <ETX>

 

 

Enable*

 

Disable - factory default. Will not send status message.

 

 

 

Enable - will send status message.

 

 

 

 

 

 

 

 

 

 

Cutter Command. This menu defines if the <ESC>SIc command which enables or disables the

 

 

 

cutter assembly is acknowledged.

 

 

 

 

Cutter Cmd (c)

 

 

 

Process - factory default. Acknowledges cutter commands.

 

Process*

 

 

 

Ignore - does not acknowledge cutter commands.

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Up Mode Command. This menu defines if the <ESC>SIC command which selects the

 

 

 

Emulation or Advanced power up mode is acknowledged.

 

 

 

 

PwrUpMod Cmd (C)

 

 

 

Process - factory default. Acknowledges the commands.

 

Process*

 

 

 

Ignore - does not acknowledge the commands.

 

 

 

 

 

 

 

 

 

 

 

 

 

End-Of-Print Distance Command. This menu defines if the <ESC>SID command is

 

 

 

acknowledged.

 

 

 

 

EOP Dist Cmd (D)

 

 

 

Process - factory default. Acknowledges the commands.

 

Process*

 

 

 

Ignore - does not acknowledge the commands.

 

 

 

 

 

 

 

 

 

 

 

 

 

Intensity Command. This menu defines if the <ESC>SId command which sets print darkness is

 

 

 

acknowledged.

 

 

 

 

Intens. Cmd (d)

 

 

 

Process - factory default. Acknowledges the commands.

 

Process*

 

 

 

Ignore - does not acknowledge the commands.

 

 

 

 

 

 

 

 

 

 

 

GL408-412e Operator Manual

4-80

PN: 9001163A

Page 116
Image 116
SATO GL408/412E manual Zero, Data preparser will be active or inactive, To the immediate commands, Acknowledged