ZGL EMULATION MODE (TABLE 4-11)

 

 

 

 

 

 

MENU

 

DESCRIPTION

 

 

 

 

 

 

 

Field Block Width Adjustment. This command allows the user to increase or decrease the width

 

 

 

of field block from the field block command ^FB, so the text line in the block can be broken at a

 

 

 

 

FB Width Adjust

 

different word.

 

0 dots*

 

 

 

The allowable range is -100to +100 dots, and the factory default is 0 dots.

 

 

 

 

 

 

 

 

 

 

 

This menu allows the operator to map the device B: to an External Memory Cartridge or PC

 

 

 

Board Flash.

 

 

 

 

Storage Select

 

 

 

B: = EMC - factory default. External Memory Cartridge.

 

B: = EMC*

 

 

 

B: = PCB Flash - PC Board Flash.

 

 

 

 

 

 

 

 

 

 

 

 

 

Network Identification. Allows the operator to assign an identification number to the network.

 

 

 

0 - factory default. Without identification.

 

 

 

 

Network ID

 

 

0*

 

1 to 999 - a range of numbers to choose for idenfication.

 

 

 

 

 

 

 

 

 

 

 

 

 

Allows the language to be selected for the character group to represent.

 

 

 

There are multiple languages from which to choose. The factory default is Standard Set.

 

 

 

 

Character Group

 

 

Standard Set*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allows further language clarification by choosing language options from a group within the

 

 

 

Standard Set of characters.

 

 

 

 

Standard Sets

 

 

 

There are multiple languages from which to choose. The factory default is USA1.

 

USA 1*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DGL EMULATION MODE (TABLE 4-12)

 

 

 

 

 

 

MENU

 

DESCRIPTION

 

 

 

 

 

 

 

Permits entry into the EMULATION Mode.

 

 

 

 

 

 

 

 

 

 

 

EMULATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allows the specific emulation to be selected or if the Select option is chosen, the menu to follow

 

 

 

will contain a list of emulation options available.

 

 

 

 

EMULATION

 

 

 

 

 

 

Select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allows the selection of the specific emulation to be selected from a list.

 

 

The allowable emulation options are: PGL for Printronics, ZGL for Zebra, TGL for TEC, IGL for

 

 

 

 

Select

 

 

DGL*

 

Intermec, SGPL for SATO, and DGL for Datamax.

 

 

 

 

 

 

 

 

 

 