RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002

SINGLE IMAGE RECORDING

The single image recording function of this VCR can be used to create image data files or animations.

NOTES:

œThe trigger at the 1 SHOT IN terminal should be on for 0.1 sec. or more.

Single Image Recording Setup

1In stop mode, press the REC/PLAY SPEED l (or j) button, to set the recording speed to “000”.

2Press the MENU button to display the MAIN MENU.

3Turn the JOG dial to select the “5.ALARM/SERIES REC SET” line, then turn the SHUTTLE ring clockwise.

øThe (ALARM/SERIES REC SET) menu appears.

<ALARM/SERIES@REC@SET>

*ALARM@SET

@@MODE@@@@@@@@@@@Y1

@@SPEED@@@@@@@@@@8H

@@DURATION@@@@@@@20S

*1@SHOT@SET

@@FIELD@@@@@@@@@@1

@@INTERVAL@@@@@@@1M

*SERIES@REC@@@@@@N

*TAPE@END@OUT@@@@8:00

4Turn the JOG dial until the “FIELD” setting is highlighted, then turn the SHUTTLE ring clockwise.

5Turn the JOG dial to set the number of fields (images) to record every time(1, 2, 3, 4, 5, 10, 30, 60), then turn the SHUTTLE ring clockwise.

6Turn the SHUTTLE ring clockwise.

7Turn the JOG dial to set the interval between each image recording (1M, 2M, 3M), then turn the SHUTTLE ring clockwise.

8Press the MENU EXIT button.

9Press the REC button.

øThe single image recording mode will be activated (the VCR will be in recording stand-by mode).

FPress the REC button one more time, or send a trigger through the 1 SHOT IN terminal on the back panel, to start the single image recording.

œThe trigger interval at the 1 SHOT IN terminal varies according to the number of images to record, but should be over 1 sec.

œAlarm recording is not possible during single image recording.

œDuring the “INTERVAL” period set for single image recording, the WARNING OUT terminal will not be 0 V even if the “NON REC” on the (WARNING OUT/CONTROL SET) menu is set to “Y”.

œIf a single image recording trigger is not received (or if the REC button is not pressed) during the duration set for “INTERVAL”, single image recording will be conducted automatically after the set duration.

œIf a single image recording trigger is received (or if the REC button is pressed) during the duration set for “INTERVAL”, single image recording will be conducted immediately.

œWhen using the 1 SHOT IN terminal, connect a make-contact switch (no voltage) between the 1 SHOT IN and COM terminals.

Recording of set number of images

 

 

 

 

 

 

 

 

 

 

 

 

Input of single

 

 

 

 

 

Input of single image

 

image recording

 

 

 

 

 

recording trigger

 

trigger

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“INTERVAL” setting (1, 2 or 3 minutes)

NOTE:

œIf a setting other than “1” is selected for “FIELD” at step 5, recording will be done in 120-hour mode. The recording speed cannot be modified.

GWhen finished, press the STOP button.

English

33

Page 34
Image 34
Sharp SRT-8168, SRT-8960, SRT-8040 instruction manual Single Image Recording Setup