SINGLE IMAGE RECORDING
The single image recording function of this VCR can be
used to create image data files or animations.

Single Image Recording Setup

1In stop mode, press the REC/PLAY SPEED l (or
j) button, to set the recording speed to 000”.
2Press the MENU button to display the MAIN MENU.
3Turn the JOG dial to select the 5.ALARM/SERIES
REC SET line, then turn the SHUTTLE ring
clockwise.
øThe (ALARM/SERIES REC SET) menu
appears.
<ALARM/SERIES@REC@SET>
*ALARM@SET
@@MODE@@@@@@@@@@@Y1
@@SPEED@@@@@@@@@@8H
@@DURATION@@@@@@@20S
*1@SHOT@SET
@@FIELD@@@@@@@@@@1
@@INTERVAL@@@@@@@1M
*SERIES@REC@@@@@@N
*TAPE@END@OUT@@@@8:00
4Turn the JOG dial until the FIELD setting is
highlighted, then turn the SHUTTLE ring clockwise.
5Turn the JOG dial to set the number of fields
(images) to record every time(1, 2, 3, 4, 5, 10, 30,
60), then turn the SHUTTLE ring clockwise.
6Turn the SHUTTLE ring clockwise.
7Turn the JOG dial to set the interval between each
image recording (1M, 2M, 3M), then turn the
SHUTTLE ring clockwise.
8Press the MENU EXIT button.
9Press the REC button.
øThe single image recording mode will be
activated (the VCR will be in recording stand-by
mode).
FPress the REC button one more time, or send a
trigger through the 1 SHOT IN terminal on the back
panel, to start the single image recording.
NOTE:
œIf a setting other than “1” is selected for FIELD at
step 5, recording will be done in 120-hour mode.
The recording speed cannot be modified.
GWhen finished, press the STOP button.
NOTES:
œThe trigger at the 1 SHOT IN terminal should be on
for 0.1 sec. or more.
œThe trigger interval at the 1 SHOT IN terminal varies
according to the number of images to record, but
should be over 1 sec.
œAlarm recording is not possible during single image
recording.
œDuring the INTERVAL period set for single image
recording, the WARNING OUT terminal will not be 0 V
even if the NON REC on the (WARNING
OUT/CONTROL SET) menu is set to “Y”.
œIf a single image recording trigger is not received (or if
the REC button is not pressed) during the duration set
for INTERVAL, single image recording will be
conducted automatically after the set duration.
œIf a single image recording trigger is received (or if the
REC button is pressed) during the duration set for
INTERVAL, single image recording will be
conducted immediately.
œWhen using the 1 SHOT IN terminal, connect a
make-contact switch (no voltage) between the 1
SHOT IN and COM terminals.
Recording of set number of images
INTERVAL” setting (1, 2 or 3 minutes)
Input of single
image recording
trigger
Input of single image
recording trigger
RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002
English 33