RF4QR/NA
CLOCK ADJUSTMENT
The time for the second and subsequent VCRs can be set to the same time as the first VCR.
A signal from a separate device can also be used to set the time for the second and subsequent VCRs to the same time as the first VCR. When using the signal from a separate device to set the time, input a 0 V signal to the CONTROL IN terminal of the first VCR for 100 ms or longer.
1Press the MENU button to display the MAIN MENU.
2Turn the JOG dial to select the “3.GENERAL SET” line, then turn the SHUTTLE ring clockwise.
3Turn the JOG dial until the “CLOCK ADJUST” setting is highlighted, then turn the SHUTTLE ring clockwise.
4Turn the JOG dial to set the hour at which the adjustment will be conducted, then turn the SHUTTLE ring clockwise.
Example
<GENERAL@SET>
TAPE@IN@MODE@@@@@STOP
TAPE@END@MODE@@@@REW
CLOCK@ADJUST@@@@@03:00
THREAD@CHECK@@@@@N
VIDEO@LOSS@@@@@@@N
CLOG@DETECT.@@@@@N
REMOTE@@@@@@@@@@@MENU
VIDEO@@@@@@@@@@@@COLOR
VERTICAL@SYNC@@@@Y
5Press the MENU EXIT button.
The setting procedure on the first VCR is now completed.
6Repeat the procedure for all the other VCRs, setting “CLOCK ADJUST” (to the same time as set on the first VCR).
NOTE:
œThis function will not operate on the day the daylight saving/standard time is changed.
NOTE:
œ The clock adjustment cannot be set to “00:00”. | Connection |
|
| VCR No. 1 | VCR No. 2 |
| CONTROL IN COM CONTROL OUT | CONTROL IN COM CONTROL OUT |
To CONTROL IN terminal
To COM terminal
SELECTING INPUT AND OUTPUT TERMINALS
The input and output terminal signals can be selected so that the VCR can be connected to older models of VCR.
1Press the MENU button to display the MAIN MENU.
2Turn the JOG dial to select the “9. OTHERS” line, then turn the SHUTTLE ring clockwise.
øThe (OTHERS) menu appears.
<OTHERS>
*ALARM@LOG
*POWER@FAILURE/DEW
*TERMINAL@SET@@@@SET1
3Turn the JOG dial until the “TERMINAL SET” setting is highlighted, then turn the SHUTTLE ring clockwise.
4Turn the JOG dial to select the desired mode, then turn the SHUTTLE ring clockwise.
SET1 . . . . . . . . . . . . . . According to indication on back panel. (Select when not connecting to an older model.)
SET2 . . . . . . . . . . . . . . CONTROL IN is set to CLOCK IN, SERIES IN is set to EJECT IN, CONTROL OUT is set to CLOCK OUT and TIMER OUT is set to EJECT OUT. (Select when connecting to an older model.)
5When finished, press the MENU EXIT button.
NOTE:
œIf set to “SET2”, the “SERIES REC” line will not appear in the (ALARM/SERIES REC SET) menu.
English | 39 |