OUTPUT TERMINALS

TAPE END OUT Terminal

œDuring recording, when the end of the tape is reached
or when the tape counter reading indicates 8 hours,
the output becomes 0V (Low). During autorepeat
recording, the output becomes 0 V (Low) for about 2
seconds only.
œTo reset the output, press the STOP or EJECT button.
TAPE END OUT Terminal Output Setting
1Press the MENU button to display the MAIN MENU.
2Turn the JOG dial to select the 5.ALARM/SERIES
REC SET line, then turn the SHUTTLE ring
clockwise.
øThe (ALARM/SERIES REC SET) menu
appears.
<ALARM/SERIES@REC@SET>
*ALARM@SET
@@MODE@@@@@@@@@@@Y1
@@SPEED@@@@@@@@@@8H
@@DURATION@@@@@@@20S
*1@SHOT@SET
@@FIELD@@@@@@@@@@1
@@INTERVAL@@@@@@@1M
*SERIES@REC@@@@@@N
*TAPE@END@OUT@@@@8:00
3Turn the JOG dial until the TAPE END OUT setting
is highlighted, then turn the SHUTTLE ring clockwise.
4Turn the JOG dial to select the desired mode, then
turn the SHUTTLE ring clockwise.
8:00 (6:00) . . The output becomes 0 V (Low)
when the tape counter reaches
8H 00M 00S (or 6H 00M 00S)
and/or when the tape reaches the
end.
END. . . . . . . The output becomes 0 V (Low)
when the tape reaches the end.
NOTES:
œIf the TAPE in the (GENERAL SET) menu is set
to T-120, 6:00 will be indicated instead of
8:00”.
œIf the SERIES REC is set to “Y” in the
(ALARM/SERIES REC SET) menu, the output
becomes 0 V (Low) for about 2 seconds when the
counter reaches 8H 00M 00S, even if the TAPE
END OUT is set to END”.
œIf the SERIES REC is set to “Y” in the
(ALARM/SERIES REC SET) menu, the output
becomes 0 V (Low) until 5 minutes have passed
after the tape reaches the end.
5Press the MENU EXIT button.

COM Terminal

œCommon GND (ground) terminal when connecting
other terminals to external devices.

TIMER OUT terminal

œDuring timer recording, the output becomes 0 V.
œDuring timer recording stand-by mode, the output is 5
V (High).
Timer recording
5V (H)
0V (L)
(Output impedance: 5.7 k)
RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002
English 45