RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002

OUTPUT TERMINALS

SW OUT Terminal

When recording, a pulse signal is output at the SW OUT terminal.

This terminal is usually connected to the switch input (SW IN) of devices like a camera switcher unit, or a quad compressor.

FIELD: 16.7 msec.

FRAME: 5 msec.

5V (H)

(Output impedance: 5.7 k) 0V (L)

SW OUT Terminal Output Setting

1Press the MENU button to display the MAIN MENU.

2Turn the JOG dial to select the “2.DISPLAY/SW OUT SET” line, then turn the SHUTTLE ring clockwise.

øThe (DISPLAY/SW OUT SET) menu appears.

<DISPLAY@SET>@@@@SET@UP

DATE@@@@@@@@@@@@@Y

TIME@@@@@@@@@@@@@Y

SPEED@@@@@@@@@@@@Y

ALARM@COUNT@@@@@@Y

<SW@OUT@SET>

TIMING@@@@@@@@@@@FIELD

FIELD@@@@@@@@@@@@1

8H@MODE@@@@@@@@@@Y

3Turn the JOG dial until the “TIMING” setting is highlighted, then turn the SHUTTLE ring clockwise.

4Turn the JOG dial to select the desired output timing, then turn the SHUTTLE ring clockwise.

FIELD. . . . . . 1 pulse is output after each set number of fields.

FRAME . . . . 1 pulse is output after each set number of frames.

5Turn the SHUTTLE ring clockwise.

6Turn the JOG dial to select the desired pulse signal interval (1, 2, 3, 4, 5, 10, 30 or 60), then turn the SHUTTLE ring clockwise.

œIf “TIMING” is set to FRAME (see step 4), “FRAME” will be indicated instead of “FIELD”.

7Turn the SHUTTLE ring clockwise.

8Turn the JOG dial to select the desired “8H” (or “6H”) mode, then turn the SHUTTLE ring clockwise.

œIf the “TAPE” in the (GENERAL SET) menu is set to “T-120”, “6H” will be indicated instead of “8H”.

Y. . . . . . . . . . When recording in 8-hour (or 6-hour) mode, a pulse signal is output.

N. . . . . . . . . . When recording in 8-hour (or 6-hour) mode, a pulse signal is not output.

9Press the MENU EXIT button.

46

English

Page 47
Image 47
Sharp SRT-8040, SRT-8960, SRT-8168 instruction manual Output Terminals, SW OUT Terminal Output Setting