OUTPUT TERMINALS
WARNING OUT Terminal
œThe WARNING OUT terminal output becomes 0 V
(Low) in accordance with the (WARNING
OUT/CONTROL SET) menu.

WARNING OUT Terminal Output Setting

1Press the MENU button to display the MAIN MENU.
2Turn the JOG dial to select the “4.WARNING
OUT/CONTR. SET line, then turn the SHUTTLE
ring clockwise.
øThe (WARNING OUT/CONTROL SET) menu
appears.
<WARNING@OUT@SET>SET@UP
ALARM@@@@@@@@@@@@Y
NON@REC@@@@@@@@@@N
MECHA.PROBLEM@@@@Y
VIDEO@LOSS@@@@@@@Y
CLOG@DETECT.@@@@@Y
<CONTROL@SET>
EJECT@MODE@@@@@@@EJECT1
OPERATION@@@@@@@@SLAVE
3Turn the SHUTTLE ring clockwise.
4Turn the JOG dial to select the desired mode, then
turn the SHUTTLE ring clockwise.
SET UP . . . . Set each item
ALL Y. . . . . . To set all items to “Y”
ALL N. . . . . . To set all items to “N”
œIf using the SET UP setting, continue with steps
5 to 7.
5Turn the JOG dial until the item for warning output is
highlighted, then turn the SHUTTLE ring clockwise.
6Turn the JOG dial to set “Y” (warning is given) or “N”
(warning is not given), then turn the SHUTTLE ring
clockwise.
ALARM. . . . . . . . . . . The output becomes 0 V
and “A” appears on the
digital display during alarm
recording
NON REC . . . . . . . . The output becomes 0 V
and “N” appears on the
digital display if the VCR
enters a mode other than
recording (i.e. recording
pause, stop mode, etc.)
during recording
MECHA. PROBLEM . . . The output becomes 0 V
and “M” appears on the
digital display when the
tape stops or other problem
with the internal mechanism
VIDEO LOSS . . . . . The output becomes 0 V
and “V” appears on the
digital display when there is
no video signal
CLOG DETECT. . . . The output becomes 0 V
and “C” appears on the
digital display when the
heads are dirty and the
recording quality
deteriorates
7Repeat steps 5 and 6 when setting other items.
8When finished, press the MENU EXIT button.
NOTES:
œThe VIDEO LOSS line does not appear if VIDEO
LOSS is set to “N” in the (GENERAL SET) menu.
œThe CLOG DETECT. line does not appear if CLOG
DETECT. is set to “N” in the (GENERAL SET) menu.
œDisplays on the digital display take precedence over
other displays.
œCanceling warning displays and output.
Press the STOP button once.
The warning display disappears from the digital
display.
Press the STOP button once more.
If MECHA. PROBLEM or CLOG DETECT.
warnings are being output, then output stops.
œIf the NON REC, VIDEO LOSS or ALARM
warning is being output, the condition immediately
before the warning output is restored and the
output stops.
œIf the system has shut down because of a
MECHA. PROBLEM warning, the output is
canceled when the ALL RESET button is pressed.
RF4QR/NA (SRT-8960 GB) Wed. May, 08/2002
English 47