Sharp XE-A303 8 @ A, Optional Programming for the Introduction of EURO, Currency exchange rate

Models: XE-A303

1 104
Download 104 pages 39.87 Kb
Page 95
Image 95
Checking the current EURO status

Part1 Part2 Part3 FOR THE MANAGER

Checking the current EURO status

You can check the EURO status currently set on the cash register. Set the manager key (MA) to the X2/Z2 position, and perform the following sequence. The current EURO status will be printed on the receipt/journal.

8: @ A

Optional Programming for the Introduction of EURO

EURO status

Some programming relating with the function of exchange key (V) cannot be changed automatically with the execution of modification operation described in the previous section. After the execution on each period, conduct the following programming depending on your needs.

Programming for Exchange Key (V)

Currency exchange rate

For period 1 and period 2, set the EURO conversion rate.

For programming details, refer to “Programming for V” on page 58.

Exchange rate entry selection

When you treat EURO currency in the exchange key, you must apply preset rate entry. So, make enable for preset rate entry for period 1 and period 2. For programming details, refer to “Programming for V” on page 58.

Cheque/credit operation

For period 1 and period 2, enable cheque/credit operation when tendering in foreign currency so that you can treat cheque and credit for EURO currency and national currency. For programming details, refer to “EURO system settings” on page 79.

Setting the date and time when the automatic modification operation for EURO should be executed Selection of compulsory/non-compulsory of execution of the automatic modification operation for EURO

You can program the scheduled date and time to execute the automatic EURO modification operation .

From ten days before the preset date, the remaining days are printed at the bottom of the daily full resetting (Z1) report as follows.

Preset data and time

Remaining days

When the above-mentioned preset date and time has come, and also when you start an entry in the REG/MGR mode, the error message “EURO CHANGE” is displayed. You cannot make any operation in the REG/MGR mode until you execute the automatic modification operation for EURO (job #800) in the X2/Z2 mode.

You can program so that you can make entries in the REG/MGR mode even when the error message is displayed.

Date and time setting will be reset after the execution of the automatic modification operation and you can program again the date and time for the next automatic modification operation.

93

Page 95
Image 95
Sharp XE-A303 8 @ A, Optional Programming for the Introduction of EURO, Part1 Part2 Part3 FOR THE MANAGER