4. Clear Text Display Module & System Parameters |
|
|
|
|
| English | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Parameter | Function | Range | Description / Notes |
|
|
|
|
|
|
|
| ||
|
|
| [Default] |
|
|
|
|
|
|
|
|
|
|
P027 | • | Skip frequency 2 (Hz) | 0 - 120.00 | See P014. |
|
|
|
|
|
|
|
| |
|
|
| [0.00] |
|
|
|
|
|
|
|
|
|
|
P028 | • | Skip frequency 3 (Hz) | 0 - 120.00 | See P014. |
|
|
|
|
|
|
|
| |
|
|
| [0.00] |
|
|
|
|
|
|
|
|
|
|
P029 | • | Skip frequency 4 (Hz) | 0 - 120.00 | See P014. |
|
|
|
|
|
|
|
| |
|
|
| [0.00] |
|
|
|
|
|
|
|
|
|
|
P031 | • | Jog frequency right (Hz) | 0 - 120.00 | Jogging is used to advance the motor by small amounts. It is | |||||||||
|
|
| [5.00] | controlled via the JOG button or with a | |||||||||
|
|
|
| the digital inputs (P051 to P053). |
|
|
|
|
|
|
| ||
|
|
|
| If jog right is enabled (DINn = 7), this parameter controls the frequency at | |||||||||
|
|
|
| which the inverter will run when the switch is closed. Unlike other setpoints, it | |||||||||
|
|
|
| can be set lower than the minimum frequency. |
|
|
|
|
|
| |||
P032 | • | Jog frequency left (Hz) | 0 - 120.00 | If jog left is enabled (DINn = 8), this parameter controls the frequency at which | |||||||||
|
|
| [5.00] | the inverter will run when the switch is closed. Unlike other setpoints, it can be | |||||||||
|
|
|
| set lower than the minimum frequency. |
|
|
|
|
|
|
| ||
P035 |
| Reverse motor direction | 0 - 1 | 0 = Normal direction control. |
|
|
|
|
|
|
| ||
|
|
| [0] | 1 = Direction control is reversed. |
|
|
|
|
|
|
| ||
P041 | • | Fixed frequency 1 (Hz) | 0 - 120.00 | Valid if P006 = 2 and P053 = 6 or 18 or P051 = P052 = P053 = 17. | |||||||||
|
|
| [5.00] |
|
|
|
|
|
|
|
|
|
|
P042 | • | Fixed frequency 2 (Hz) | 0 - 120.00 | Valid if P006 = 2 and P052 = 6 or 18 or P051 = P052 = P053 = 17. | |||||||||
|
|
| [10.00] |
|
|
|
|
|
|
|
|
|
|
P043 | • | Fixed frequency 3 (Hz) | 0 - 120.00 | Valid if P006 = 2 and P051 = 6 or 18 or P051 = P052 = P053 = 17. | |||||||||
|
|
| [15.00] |
|
|
|
|
|
|
|
|
|
|
P044 | • | Fixed frequency 4 (Hz) | 0 - 120.00 | Valid if P006 = 2 and P051 = P052 = P053 = 17. |
|
|
|
|
| ||||
|
|
| [20.00] |
|
|
|
|
|
|
|
|
|
|
P045 |
| Inversion fixed setpoints for | 0 - 7 | Sets the direction of rotation for the fixed frequency: |
|
|
| ||||||
|
| fixed frequencies 1 - 4 | [0] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FF 1 | FF 2 |
| FF 3 |
| FF 4 |
| |
|
|
|
|
| P045 = 0 | ⇒ | ⇒ |
| ⇒ |
| ⇒ |
| |
|
|
|
|
| P045 = 1 | ⇐ | ⇒ |
| ⇒ |
| ⇒ |
| |
|
|
|
|
| P045 = 2 | ⇒ | ⇐ |
| ⇒ |
| ⇒ |
| |
|
|
|
|
| P045 = 3 | ⇒ | ⇒ |
| ⇐ |
| ⇒ |
| |
|
|
|
|
| P045 = 4 | ⇒ | ⇒ |
| ⇒ |
| ⇐ |
| |
|
|
|
|
| P045 = 5 | ⇐ | ⇐ |
| ⇒ |
| ⇒ |
| |
|
|
|
|
| P045 = 6 | ⇐ | ⇐ | ⇐ |
|
| ⇒ |
| |
|
|
|
|
| P045 = 7 | ⇐ | ⇐ | ⇐ | ⇐ |
|
|
|
|
|
|
|
| ⇒ Fixed setpoints not inverted. |
|
|
| |||
|
|
|
| ⇐ | Fixed setpoints inverted. |
|
|
| ||
P046 • | Fixed frequency 5 (Hz) | 0 - 120.00 Valid if P006 = 2 and P051 = P052 = P053 = 17. | ||||||||
|
| [25.00] |
|
|
|
|
|
|
|
|
P047 • | Fixed frequency 6 (Hz) | 0 - 120.00 Valid if P006 = 2 and P051 = P052 = P053 = 17. | ||||||||
|
| [30.00] |
|
|
|
|
|
|
|
|
P048 • | Fixed frequency 7 (Hz) | 0 - 120.00 Valid if P006 = 2 and P051 = P052 = P053 = 17. | ||||||||
|
| [35.00] |
|
|
|
|
|
|
|
|
P050 | Inversion fixed setpoints for | 0 - 7 | Sets the direction of rotation for the fixed frequency: | |||||||
| fixed frequencies 5 - 7 | [0] |
|
|
|
|
|
|
|
|
|
|
|
|
|
| FF 5 | FF 6 |
| FF 7 |
|
|
|
|
| P050 = 0 | ⇒ | ⇒ |
| ⇒ |
| |
|
|
|
| P050 = 1 | ⇐ | ⇒ |
| ⇒ |
| |
|
|
|
| P050 = 2 | ⇒ | ⇐ |
| ⇒ |
| |
|
|
|
| P050 = 3 | ⇒ | ⇒ |
| ⇐ |
| |
|
|
|
| P050 = 4 | ⇒ | ⇒ |
| ⇒ |
| |
|
|
|
| P050 = 5 | ⇐ | ⇐ |
| ⇒ |
| |
|
|
|
| P050 = 6 or 7 | ⇐ | ⇐ | ⇐ |
|
| |
|
|
|
| ⇒ Fixed setpoints not inverted. |
|
|
| |||
|
|
|
| ⇐ | Fixed setpoints inverted. |
|
|
|
© STÖBER plc 1997
19 | 05.02.01 |
|