English

 

4.

Clear Text Display Module & System Parameters

 

 

 

 

 

 

Parameter

Function

Range

Description / Notes

 

 

 

 

 

[Default]

 

 

 

 

 

 

P203

I gain (%)

0.00 -

Integral gain.

 

 

 

 

 

 

99.99

0.01% corresponds to the longest integral response time.

 

 

 

[0.00]

 

 

 

 

 

 

P205

Sample interval (x 25 ms)

1 - 2400

Sampling interval of feedback sensor.

 

 

 

[1]

 

 

 

 

 

 

P206

Transducer filtering

0 - 255

0

=

Filter off.

 

 

 

 

 

[0]

1

- 255 = Low pass filtering applied to transducer.

 

P207

Integral capture range (%)

0 - 100

Percentage error above which integral term is reset to zero.

 

 

 

[100]

 

 

 

 

 

 

P208

 

Transducer type

0 - 1

0

= An increase in motor speed causes an increase in sensor

 

 

 

[0]

1

 

voltage/current output.

 

 

 

 

 

 

= An increase in motor speed causes a decrease in sensor

 

 

 

 

 

 

voltage/current output.

 

 

P210

 

Transducer reading (%)

0.0 - 100.0

Read only. Value is a percentage of full scale of the PI input.

 

 

 

[-]

 

 

 

 

 

 

P211

0% setpoint

0.00-

Value of P210 to be maintained for 0% setpoint.

 

 

 

100.00

 

 

 

 

 

 

 

 

 

[0.00]

 

 

 

 

 

 

P212

100% setpoint

0.00-

Value of P210 to be maintained for 100% setpoint.

 

 

 

100.00

 

 

 

 

 

 

 

 

 

[100.00]

 

 

 

 

 

 

P220

PI frequency cut-off

0 - 1

0

=

Normal operation

 

 

 

 

 

[0]

1

= Switch off inverter at or below minimum frequency.

 

P331

 

Analogue mode

0 - 4

0

=

Internal potentiometer only

 

 

 

[2]

1

= External analogue input only

 

 

 

 

2

= Internal potentiometer + external analogue input

 

 

 

 

3

= Internal potentiometer fine, external input coarse

 

 

 

 

4

= Internal potentiometer coarse, external input fine

 

P332

 

Fine adjustment (%)

0 - 100

Percentage of fine tuning adjustment for P331 = 3 or 4.

 

 

 

[10]

 

 

 

 

 

 

P700

 

 

 

 

Specific to PROFIBUS-DP. See PROFIBUS Handbook for further

P701

 

 

 

 

 

 

details. (Access only possible with P099 = 1.)

P702

 

 

 

 

 

 

 

 

 

P723

 

State of digital inputs

0 - 7

0

=

DIN3

DIN2

DIN1

 

 

 

[-]

0

0

0

 

 

 

 

 

1

=

0

0

1

 

 

 

 

 

2

=

0

1

0

 

 

 

 

 

3

=

0

1

1

 

 

 

 

 

4

=

1

0

0

 

 

 

 

 

5

=

1

0

1

 

 

 

 

 

6

=

1

1

0

 

 

 

 

 

7

=

1

1

1

 

P880

 

 

 

Specific to PROFIBUS-DP. See PROFIBUS Handbook for further

 

 

 

 

details. (Access only possible with P099 = 1.)

 

 

 

 

 

 

 

 

 

 

© STÖBER plc 1998

05.02.01

26