English |
| 4. | Clear Text Display Module & System Parameters | ||||||
|
|
|
|
|
| ||||
Parameter | Function | Range | Description / Notes |
|
| ||||
|
|
| [Default] |
|
|
|
|
|
|
P203 | • | I gain (%) | 0.00 - | Integral gain. |
|
|
| ||
|
|
| 99.99 | 0.01% corresponds to the longest integral response time. | |||||
|
|
| [0.00] |
|
|
|
|
|
|
P205 | • | Sample interval (x 25 ms) | 1 - 2400 | Sampling interval of feedback sensor. | |||||
|
|
| [1] |
|
|
|
|
|
|
P206 | • | Transducer filtering | 0 - 255 | 0 | = | Filter off. |
|
| |
|
|
| [0] | 1 | - 255 = Low pass filtering applied to transducer. |
| |||
P207 | • | Integral capture range (%) | 0 - 100 | Percentage error above which integral term is reset to zero. | |||||
|
|
| [100] |
|
|
|
|
|
|
P208 |
| Transducer type | 0 - 1 | 0 | = An increase in motor speed causes an increase in sensor | ||||
|
|
| [0] | 1 |
| voltage/current output. |
|
| |
|
|
|
| = An increase in motor speed causes a decrease in sensor | |||||
|
|
|
|
|
| voltage/current output. |
|
| |
P210 |
| Transducer reading (%) | 0.0 - 100.0 | Read only. Value is a percentage of full scale of the PI input. | |||||
|
|
|
|
|
|
|
|
| |
P211 | • | 0% setpoint | 0.00- | Value of P210 to be maintained for 0% setpoint. | |||||
|
|
| 100.00 |
|
|
|
|
|
|
|
|
| [0.00] |
|
|
|
|
|
|
P212 | • | 100% setpoint | 0.00- | Value of P210 to be maintained for 100% setpoint. | |||||
|
|
| 100.00 |
|
|
|
|
|
|
|
|
| [100.00] |
|
|
|
|
|
|
P220 | • | PI frequency | 0 - 1 | 0 | = | Normal operation |
|
| |
|
|
| [0] | 1 | = Switch off inverter at or below minimum frequency. |
| |||
P331 |
| Analogue mode | 0 - 4 | 0 | = | Internal potentiometer only | |||
|
|
| [2] | 1 | = External analogue input only | ||||
|
|
|
| 2 | = Internal potentiometer + external analogue input | ||||
|
|
|
| 3 | = Internal potentiometer fine, external input coarse | ||||
|
|
|
| 4 | = Internal potentiometer coarse, external input fine |
| |||
P332 |
| Fine adjustment (%) | 0 - 100 | Percentage of fine tuning adjustment for P331 = 3 or 4. | |||||
|
|
| [10] |
|
|
|
|
|
|
P700 |
|
|
|
| Specific to | ||||
P701 | • |
|
|
| |||||
|
|
| details. (Access only possible with P099 = 1.) | ||||||
P702 |
|
|
|
|
|
|
|
|
|
P723 |
| State of digital inputs | 0 - 7 | 0 | = | DIN3 | DIN2 | DIN1 | |
|
|
| 0 | 0 | 0 |
| |||
|
|
|
| 1 | = | 0 | 0 | 1 |
|
|
|
|
| 2 | = | 0 | 1 | 0 |
|
|
|
|
| 3 | = | 0 | 1 | 1 |
|
|
|
|
| 4 | = | 1 | 0 | 0 |
|
|
|
|
| 5 | = | 1 | 0 | 1 |
|
|
|
|
| 6 | = | 1 | 1 | 0 |
|
|
|
|
| 7 | = | 1 | 1 | 1 |
|
P880 |
|
|
| Specific to | |||||
|
|
|
| details. (Access only possible with P099 = 1.) | |||||
|
|
|
|
|
|
|
|
|
|
© STÖBER plc 1998
05.02.01 | 26 |
|