English

2. Installation

2.3 Electrical Installation

Remove the four M5 cross-head screws on the inverter's cover to access the electrical terminals(see Figure 3 and Figure 4).

Notes: (1) Refer to the electrical data table for cable sizes (see section 6).

(2)We recommend introducing a `drip loop' when connecting the mains and control cables(see Figure 5).

CAUTION

The printed circuit boards contain CMOS components that are particularly sensitive to static electricity. For this reason, avoid touching the boards or components with your hands or metal objects.

Mains Connector *

 

LED

LED

 

L1 L2 L3

 

(Green)

(Yellow)

 

 

 

 

 

Control Cable Connector

 

 

 

 

(PL800)

 

 

 

12

1

 

-

+

 

1

4

 

 

 

OPm2 Connector

Control

 

 

 

(SK200)

Potentiometer

 

 

 

(R314)

 

 

Jumpers for

 

Jumpers for

 

PI Input Type

Analogue Input Type

 

Default = V

 

Default = V

V

JP303

V

JP301

I

JP302

I

JP300

Note: Jumper in ‘V’ position = voltage input (default) Jumper in ‘I’ position = current input

IMPORTANT

Ensure that the following tightening torques are used:

Electrical terminal screws:

1.1 Nm

Access cover retaining screws:

4.0 Nm

Gland hole covers:

1.0 Nm

*Check that the supply voltage is correct for the COMBIMASTERused by referring to the voltage code part of the order number (see section 6).

Figure 1: Electrical Connection Diagram

© STÖBER plc 1998

05.02.01