7.3 Electro-Magnetic Compatibility (EMC)
Class 2: Filtered Industrial (Class A)
This level of performance will allow the manufacturer/assembler to
EMC Phenomenon | Standard | Level |
|
|
|
Emissions: |
|
|
Radiated Emissions | EN 55011 | Level A1 |
Conducted Emissions | EN 55011 | Level A1 |
|
|
|
Immunity: |
|
|
Supply Voltage Distortion | IEC |
|
Voltage Fluctuations, Dips, Unbalance, | IEC |
|
Frequency Variations |
|
|
Magnetic Fields | EN | 50 Hz, 30 A/m |
Electrostatic Discharge | EN | 8 kV air discharge |
Burst Interference | EN | 2 kV power cables, 2 kV control |
Radio Frequency Electromagnetic Field, | ENV 50 140 | |
amplitude modulated |
| power and signal lines |
Class 3: Filtered - for residential, commercial and light industry (Class B)
This level of performance will allow the manufacturer / assembler to
EMC Phenomenon | Standard | Level |
|
|
|
Emissions: |
|
|
Radiated Emissions | EN 55022 | Level B1 |
Conducted Emissions | EN 55022 | Level B1 |
|
|
|
Immunity: |
|
|
Electrostatic Discharge | EN | 8 kV air discharge |
Burst Interference | EN | 1 kV power cables, 0.5 kV control |
Note: The CombiDrive® is intended exclusively for professional applications. Therefore, it does not fall within the scope of the harmonics emissions specification EN
7.4 Environmental Aspects
Transport and Storage
Protect the CombiDrive® against physical shocks and vibration during transport and storage. The unit must also be protected against water (rainfall) and excessive temperatures (see section 6).
The packaging is
Dismantling and Disposal
The component parts can be recycled, disposed of in accordance with local requirements or returned to the manufacturer.
Documentation
This handbook is printed on
© STÖBER plc 1997
33 | 05.02.01 |
|