4. Clear Text Display Module & System Parameters

English

 

 

 

 

 

Parameter

Function

Range

Description / Notes

 

 

 

[Default]

 

 

 

 

 

P123

Enable/disable JOG button

0 - 1

0 = JOG button disabled.

 

 

[1]

1 = JOG button enabled (only possible if P007 = 1).

 

P124

Enable/disable and buttons

0 - 1

0 =

and

buttons disabled.

 

 

[1]

1 =

and buttons enabled (only possible if P007 = 1).

 

 

 

Note:

This applies for frequency adjustment only. The buttons can

 

 

 

 

 

still be used to change parameter values.

 

P125

Reverse direction inhibit

0 - 1

0 =

Reverse direction disabled. Inhibits reverse commands from

 

 

[1]

 

ALL sources (reverse RUN commands result in forward rotation)

1 = Normal operation (FORWARD/REVERSE operation allowed)

P131

Frequency setpoint (Hz)

0.00 -120.00

 

 

[-]

P132

Motor current (A)

0.0 - 99.9

 

 

[-]

P134

DC link voltage (V)

0 - 1000

 

 

[-]

P135

Motor RPM

0 - 40000

 

 

[-]

P137

Output voltage (V)

0 - 1000

 

 

[-]

Read-only parameters. These are copies of the values selected by P001 but can be accessed directly via the serial link.

P140

 

Most recent fault code

0 - 9999

The last recorded fault code (see section 5) is stored in this

 

 

 

[-]

parameter. It is cleared when the inverter is reset.

 

 

 

 

This is a copy of the code stored in P930.

 

 

 

 

 

P141

 

Most recent fault code -1

0 - 9999

This parameter stores the last recorded fault code prior to that stored

 

 

 

[-]

in P140/P930.

 

P142

 

Most recent fault code -2

0 - 9999

This parameter stores the last recorded fault code prior to that stored

 

 

 

[-]

in P141.

 

P143

 

Most recent fault code -3

0 - 9999

This parameter stores the last recorded fault code prior to that stored

 

 

 

[-]

in P142.

 

P151

Green LED function

0 - 5

0

= Off

 

 

 

 

[4]

1

= On

 

 

 

 

 

2

= Fault mode:

On = Tripped

 

 

 

 

3

 

Flashing = Warning

 

 

 

 

= Running mode:On = Motor running

 

 

 

 

stationary

Flashing = Inverter on but motor

 

 

 

 

 

 

 

 

 

4

= Default mode (see table in section 3.6)

 

 

 

 

5

= Not used

 

P152

Yellow LED function

0 - 5

0

= Off

 

 

 

 

[5]

1

= On

 

 

 

 

 

2

= Fault mode:

On = Tripped

 

 

 

 

3

 

Flashing = Warning

 

 

 

 

= Running mode:On = Motor running

 

 

 

 

stationary

Flashing = Inverter on but motor

 

 

 

 

 

 

 

 

 

4

= Not used

 

 

 

 

 

5

= Default mode (see table in section 3.6)

P201

 

PI closed loop mode

0 - 2

0 = Normal operation (closed loop control disabled).

 

 

 

[0]

1 = Not used

 

 

 

 

 

2 = Closed loop control using PI input for transducer feedback.

P202

P gain (%)

0.0 - 999.9

Proportional gain.

 

 

 

 

[1.0]

 

 

 