8. Accessoires

8.2 Clear text Display Module (Opm2) in IP55 housing

see chap. 4.1.

This section only applies for users who intend using the optional Clear Text Display module (OPm2) to control the operation of the CombiDrive® .

The OPm2 module provides a multi-language user-friendly interface to the CombiDrive® . The display is menu- driven and provides information in simple text form. It also includes built-in context-sensitive Help screens.

As well as enabling direct control of the motor, the OPm2 extends the functionality of the CombiDrive® by providing access to a comprehensive range of adjustable parameters. Setting these parameters will allow you to customise the operation of the CombiDrive® to meet almost any application requirement.

JOG

 

 

 

Button

 

 

 

 

 

LCD

 

 

 

Screen

 

RUN / STOP

 

 

Inducator2

 

FORWARD / REVERSE

 

 

 

 

Button6

 

RUN

 

UP / INCREASE

Button

3

 

Frequency7

 

 

 

 

STOP

 

DOWN / DECREASE

Button4

Frequency8

 

MENU

Parameterisation

Button4

Button

9

 

 

 

1Pressing this button while the motor is stopped causes it to start and run at the preset jog frequency. The motor stops as soon as the button is released. Pressing this button while the motor is running has no effect. Disabled if P007 or 123 = 0.

2Green indicates that the motor is running.

Flashing green indicates that the motor is ramping up or down. Red indicates that the motor is stationary.

Flashing red indicates a fault condition.

3Press to start the inverter. Disabled if P007 or P121 = 0.

4Press to stop the inverter.

5Changes the display to show the menu options. Pressing and holding this button down and then pressing the button causes the Help screen to be displayed.

6Press to change the direction of rotation of the motor. REVERSE is indicated by a minus sign (values <100) or a flashing decimal point (values > 100). Disabled if P007 or P122 = 0.

7Press to INCREASE frequency. Used to change parameter numbers or values to higher settings during the parameterisation procedure.

Disabled if P124 = 0.

9Press to access parameters. Disabled if P051 - P053 = 14 when using digital inputs.