Command Interface

5.2.23Read_AS-i_Slave_ID1

Purpose

With this call, the ID1 code of an AS-i slave can be read out directly over the AS-i cable. The call is intended for diagnostic purposes and is not required in the normal master mode.

Structure of the Job Data in the Send Buffer

Bank Byte

20

21

Meaning

Command number: 37 H

AS-i slave address

Structure of the Job Data in the Receive Buffer

Bank Byte

2

0

 

 

21

22

 

 

Meaning

 

 

 

 

 

 

Bit 7

Bit 4

Bit 3

Bit 0

 

 

 

 

 

Echo of the command number: 37 H

 

 

 

Command status

 

 

 

 

 

reserved

 

Extended ID1 code

 

 

 

 

 

 

SIMATIC NET CP 243-2 AS-i Master

5-49

C79000-G8976-C142/02

Page 117
Image 117