Command Interface

5.2.28Write_AS-i_Slave_Parameter_String

Purpose

With this call, a parameter string complying with AS-i slave profile 7.4 can be sent to the AS-i master that passes on the string to the AS-i slave address specified in the send buffer.

With this call, a send buffer with a maximum of 223 bytes is transferred to the AS-i master. The actual number of parameter bytes to be sent to the AS-i slave is calculated by the AS-i master from byte 2 of the send buffer (number of parameter bytes).

The information in the string is not evaluated by the AS-i master and is passed on to the AS-i slave transparently.

As long as the string transfer is active, there is no user/analog data exchange with the addressed AS-i slave.

Structure of the Job Data in the Send Buffer

Bank

2

2

2

2

2

...

...

...

Byte

0

1

2

3

4

...

...

...

Meaning

40H

Slave address

Number of parameter bytes

String byte (1)

String byte (2)

.....

String byte (n±1)

String byte (n)

Maximum value for n=220

Structure of the Job Data in the Receive Buffer

Bank Byte

20

21

Meaning

Echo of the command number: 40 H

Command status

5-54

SIMATIC NET CP 243-2 AS-i Master

C79000-G8976-C142/02

Page 122
Image 122