Command Interface

Table 5-2 , continued

SI

Q1.0, 1

//Select bank 5

BMW

VW748, AQW0, 8

//V memory ±> bank

RI

Q1.0, 1

//Select bank 6

SI

Q1.1, 1

//Select bank 6

BMW

VW764, AQW0, 8

//V memory ±> bank

SI

Q1.0, 1

//Select bank 7

BMW

VW780, AQW0, 8

//V memory ±> bank

RI

Q1.0, 3

//Select bank 8

SI

Q1.3, 1

//Select bank 8

BMW

VW796, AQW0, 8

//V memory ±> bank

SI

Q1.0, 1

//Select bank 9

BMW

VW812, AQW0, 8

//V memory ±> bank

RI

Q1.0, 1

//Select bank 10

SI

Q1.1, 1

//Select bank 10

BMW

VW828, AQW0, 8

//V memory ±> bank

SI

Q1.0, 1

//Select bank 11

BMW

VW844, AQW0, 8

//V memory ±> bank

RI

Q1.0, 2

//Select bank 12

SI

Q1.2, 1

//Select bank 12

BMW

VW860, AQW0, 8

//V memory ±> bank

SI

Q1.0, 1

//Select bank 13

BMW

VW876, AQW0, 8

//V memory ±> bank

RI

Q1.0, 1

//Select bank 14

SI

Q1.1, 1

//Select bank 14

BMW

VW892, AQW0, 8

//V memory ±> bank

SI

Q1.0, 1

//Select bank 15

BMW

VW908, AQW0, 8

//V memory ±> bank

RI

 

Q1.0,6

//Select bank 0

SI

Q1.6, 1

//ASI_COM

//Fetch response from CP

 

LD

 

Q1.6

//ASI_COM

A

I1.6

//ASI_RESP

RI

Q1.0, 6

//Select bank 2

SI

Q1.1, 1

//Select bank 2

BMW

AIW0, VW400, 8

//Bank ±> V memory

SI

Q1.0, 1

//Select bank 3

BMW

AIW0, VW416, 8

//Bank ±> V memory

RI

Q1.0, 2

//Select bank 4

SI

Q1.2, 1

//Select bank 4

BMW

AIW0, VW432, 8

//Bank ±> V memory

SI

Q1.0, 1

//Select bank 5

BMW

AIW0, VW448, 8

//Bank ±> V memory

RI

Q1.0, 1

//Select bank 6

SI

Q1.1, 1

//Select bank 6

BMW

AIW0, VW464, 8

//Bank ±> V memory

SI

Q1.0, 1

//Select bank 7

BMW

AIW0, VW480, 8

//Bank ±> V memory

RI

Q1.0, 3

//Select bank 8

SI

Q1.3, 1

//Select bank 8

BMW

AIW0, VW496, 8

//Bank ±> V memory

SIMATIC NET CP 243-2 AS-i Master

5-5

C79000-G8976-C142/02

Page 73
Image 73
Siemens CP 243-2 installation instructions Q1.0 Select bank