5. SYSTEM PARAMETERS

 

 

 

English

Parameter

 

Function

 

Range

 

Description / Notes

 

 

 

 

[Default]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P947

P958

P963

P967

P968

P970

P971 EEPROM storage control

0 - 1

 

[1]

 

 

 

 

Specific to PROFIBUS-DP. See PROFIBUS Handbook for further

details.

Access only possible with P099 = 1

0 = Changes to parameter settings (including P971) are lost when power is removed.

1 = Changes to parameter settings are retained during periods when power is removed.

WARNING: When using the serial link to update the parameter set held in EEPROM, care must be taken not to exceed the maximum number of write cycles to this EEPROM - this is approximately 50,000 write cycles. Exceeding this number of write cycles would result in corruption of the stored data and subsequent data loss. The number of read cycles are unlimited.

© Siemens plc 1997G85139-H1750-U049-B

33

26/09/97

 

Page 33
Image 33