4 Electromagnetic Compatibility

4

 

The Panel PC 670/870 meets the requirements of German EMC laws as well as European Directives concerning EMC.

The following includes information on interference immunity of the Panel PC 670/870 and on interference suppression.

The Panel PC 670/870s have been conceived as installation devices with Protection Class IP65 on the front side. Their installation in grounded metal cabinets (e.g. 8 MC cabinet according to the NV21 catalog) guarantees compliance with EN 61000-4-2 standards.

The touch panel versions without a USB interface on the front side meet the requirements complying with NEMA 4.

Pulse shaped interference

Pulse shaped interference

Tested with

Corresponds to

 

 

Severity Level

Electrostatic discharge

8 kV

3

(Air Discharge)

complying with

4 kV

2

(Contact

EN 61000-4-2

 

Discharge)

Burst Impulses (rapid,

2 kV (Power Line)

3

 

temporary interference)

2 kV (Process Data Line)

3

 

according to EN 61000-4-4

 

 

 

 

 

 

 

High-energy single Impulse

 

 

 

(Surge) according to

 

 

 

EN 61000-4-5

 

 

 

(24 V model only with

 

 

 

protective lightning conductor

 

 

 

KT Type A D 24 V, Order No.

 

 

 

DSN:919253)

 

 

 

Asymmetric Connection

2 kV (Power Line)

3

 

Symmetric Connection

1 kV (Power Line)