Notice

Check whether the active Partition C still exists. Use the MS-DOS tool fdisk, for example, to do this. If the active partition is no longer available, recreate it, observing the following:

If the active Partition C is no longer available and the EasyRestore program is started, data is lost on Partition D.

Observe the following procedures during the restore process to reset the initial state of drive C.

Windows NT, Windows 98

Call in the BIOS, select the settings Main Boot Options and check that menu item Boot Sequence. The menu item must be set so that it is possible to boot from the CD-ROM.

Insert the Restore-CD and restart the Panel PC anew.

Affirm the license agreement and read the warning message. After confirmation, the original image is restored on drive C.

Windows 2000, Windows XP

Call in the BIOS, select the settings Main Boot Options and check that menu item Boot Sequence. The menu item must be set so that it is possible to boot from disk.

Insert the Restore disk and Restore CD 1 and restart the Panel PC anew.

Insert Restore-CD 2 following the corresponding request. Affirm the license agreement and read the warning message.

After confirmation, the original image is restored on drive C. Follow the instructions which appear on the screen.

Recovery CD

Note

The Recovery-CD can be used for the installation or restoring the operating system. Only those drivers required for that specific operating system are installed.

The drivers required by the Panel PC 670/870 are contained on the

Panel PC 670/870 Documentation & Drivers CD. A setup is necessary in order to install the drivers. This is on the CD under:

InstallshieldPC670_870\setup.exe

SIMATIC Panel PC 670/870 Start-Up Instructions