Identcode ordering system

Dulcodes UV-Desinfektionsanlage

 

 

Identcode ordering system

Please enter the identcode on the device label into the grey box below.

S 2 C a

S i g m a C o n t ro l Ty p e ( S 2 C a )

HM

Power end, diaphragm

 

 

Pump typ: (figures 1+2 =back pressure [bar],figures 3-5 =feed rate [l/h])

 

16050

16 bar;

60 l/h

 

16090

16 bar;

95 l/h

 

16130

16 bar; 136 l/h

 

12050*

10 bar;

60 l/h

 

12090*

10 bar;

95 l/h

 

12130*

10 bar; 136 l/h

 

07120

7 bar; 148 l/h

 

07220

7 bar; 232 l/h

 

04350

4 bar; 350 l/h * for SST versions, max. 12 bar

 

Liquid end materials:

PV

PVDF

SS

Stainless steel

Seal material:

TPTFE seal

Displacement element:

0Standard diaphragm

1Double diaphragm with rupture indicator incorporating “Pump stopping” function

2 Double diaphragm with rupture indicator incorporating “Pump alarm” function

Liquid end version:

0No springs

1With 2 valve springs,Hastelloy C,0.1 bar

4With relief valve,Viton® seal,no valve spring

5 With relief valve,Viton® seal,with valve spring

Hydraulic connection:

0Standard threaded connector (according to technical data)

1 Union nut and PVC insert

2 Union nut and PP insert

3 Union nut and PVDF insert

4 Union nut and stainless steel insert

7 Union nut and PVDF hose nozzle

8 Union nut and stainless steel hose nozzle

Version:

0With ProMinent® logo

1Without ProMinent® logo

Electrical power supply:

U1 ph 100-230 V ±10 %, 50/60 Hz

Cable and plug:

A2 m European

B 2 m Swiss

C 2 m Australian

D 2 m USA

 

Relays:

0

No relay

1

With fault indicating relay (N/C)

3

With fault indicating relay (N/O)

4

As 1 with pacing relay

5

As 3 with pacing relay

F

Power relay N/C

G

Power relay N/O

 

Control variant:

0

Manual + external with pulse control

1

Manual + external + pulse control

 

+ analogue

4

As 0 + process-timer

5

As 1 + process-timer

P

PROFIBUS®

 

 

 

 

Access code:

 

0

No access code

 

1

With access code

 

 

 

 

 

 

Metering monitor:

 

 

 

 

0

Input with pulse evaluation

 

 

 

 

1

Input with permanent contact

 

 

 

 

 

 

evaluation

 

 

 

 

 

 

 

 

Stroke length

 

 

 

 

 

 

 

 

adjustment:

 

 

 

 

 

 

0

Manual

 

 

 

 

 

 

C

Manual + calibration

 

 

 

 

 

 

 

 

 

S2Ca

___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___

 

 

Viton® is a registered trademark of DuPont Dow Elastomers.

Page 10

ProMinent®

Page 10
Image 10
Sigma S2Ba, S2Ca warranty Identcode ordering system Dulcodes UV-Desinfektionsanlage