Features of the S2Ca metering pumps

Dulcodes UV-Desinfektionsanlage

 

 

2

yellow/NO

1

green/NC

4

white/NO

3

brown/C

Technical data, relay (control version)

Pump type S2Ca

3

Relay

Fault-indicating relay

Fault-indicating relay + pulse generator

Relay type

Fault-indicating relay

pulse generator

Fault-indicating relay

1

 

 

 

 

Voltage, max:

250 V 50/60 Hz

24 V DC

24 V 50/60 Hz

4

Current, max.

2 A (ohmic)

100 mA

100 mA

 

 

 

 

 

 

 

Hook up duration

 

100 ms

 

 

Behaviour

see Identcode

see Identcode

see Identcode

 

 

 

 

 

 

Service life

> 200 000 cycles*

> 50 x 106 (10 V 10 mA)

> 200 000 cycles

fault indicating relay

 

 

 

 

 

Relay type

Power relay

 

 

 

 

 

 

 

pacing relay

Voltage, max.

250 V (50/60 Hz)

 

 

2

2

green/NC

Current, max.

16 A (ohmic)

Hook up duration

 

Behaviour

see Identcode

 

 

Service life

> 30 000 cycles*

 

 

1

white/NO

* in the case of nominal load

4

brown/C

The contacts are zero volt.

N/C fault indicating relay - the relay closes immediately after the power is switched on and opens in the event of a fault.

N/O fault indicating relay, the relay closes in the event of a fault.

Use suitable interference suppression (e.g. RC glands) when connecting inductive loads.

Page 36

ProMinent®

Page 36
Image 36
Sigma S2Ba, S2Ca warranty Relay type Power relay