Sigma S2Ca 3.1.8Electrical data, pacing relay ÒSigmaÓ, 3.1.9Sound intensity level, Technical data

Models: S2Ca S2Ba

1 63
Download 63 pages 60.43 Kb
Page 29
Image 29
3.1.8Electrical data, pacing relay ÒSigmaÓ

Dulcodes UV-Desinfektionsanlage

Technical data

 

 

Blue

-

 

 

Brown

+

 

 

b) Namur sensor, intrinsically (Identcode characteristic ÒStroke sensorÓ: 3)

WARNING

¥EX-pump only: intrinsically safe installations must be installed and checked by persons with Òrecognised skillsÓ!

¥EX-pump only: observe documents supplied with the sensor!

5-25 V DC, Namur type and/or DIN 19234, zero volt design. Rated voltage: 8 V DC (Ri ~ 1 k)

Power consumption:

Active surface, uncovered > 3 mA Active surface, covered < 1 mA

Rated switching distance: 1.5 mm

The monitor/feeder must be capable of evaluating current changes in order to indicate diaphragm rupture!

3.1.8Electrical data, pacing relay ÒSigmaÓ

Relay input

(power supply for the relay board)

Input voltage

Mains frequency

Power consumption

200/230 V AC (180-254 V)

50/60 Hz

10 mA (230 V/50 Hz)

100/115 V AC (90-134 V)

50/60 Hz

15 mA (115 V/60 Hz)

 

 

 

 

24 V DC (20-28 V)

-

 

10 mA at 24 V DC

Relay output

 

 

 

 

 

 

Voltage, max.

24 V DC

 

 

Current, max.

100 mA

 

 

 

 

Hook up duration

100 ms

 

 

Standard

adjustable

 

 

The contacts are zero volt.

 

 

 

3.1.9Sound intensity level

The sound intensity level is < 70 dB (A)

at maximum stroke, maximum stroking rate, maximum back pressure (water) in accordance with DIN EN 12639 (noise measurement in fluid pumps)