Dulcodes | Settings |
|
|
NOTE
If a remainder occurs when the factor is processed, the S2Ca counts up the remainder values. When the sum reaches or exceeds Ò1Ó the S2Ca will activate a stroke. This ensures that the stroke number corresponds exactly to the factor throughout the dosing operation.
The number of input pulses which have not been processed are stored by the S2Ca in the stroke memory. The stroke buffer is limited to the batch size when memory is not activated (- with “Memory” at 65535 stokes). You can delete it by switching to a different operating mode.
You can optimally adapt the S2Ca to the respective process, e.g. in connection with contact water meters.
ÒMemoryÓ extension function
The “memory” extension function can be optionally activated (“mem” appears in the LCD display). When “Memory” is activated the S2Ca adds any strokes which could not be carried out up to the maximum capacity of the stroke buffer – 65535 strokes. If this maximum capacity is exceeded the pump will register a fault.
7.4.4Settings for ÒbatchÓ operating mode (BATCH menu)
In addition to those settings menus described in 7.5, there is an additional BATCH menu in the overall SET menu for the “batch” operating mode.
P | P | Mem | Batch | P | Mem | Batch | P |
|
| ||||||
|
|
|
| ||||
Set | Set |
| Set | L |
| ||
Continuous |
|
|
|
|
|
|
|
display |
|
|
|
|
|
|
|
The “batch” operating mode is a variant of the “contact” operating mode (see 7.4.3).
You can
The “batch” operating mode is intended for large dosing quantities.
Metering can be actuated by pressing the
The number of input pulses which have not been processed are stored by the S2Ca in the stroke memory. The stroke buffer is limited to the batch size when memory is not activated (- with “Memory” at 65535 stokes). You can delete it by switching to a different operating mode.
ÒMemoryÓ extension function
The “memory” extension function can be optionally activated (“mem” appears in the LCD display). When “Memory” is activated the S2Ca adds any strokes which could not be carried out up to the maximum capacity of the stroke buffer – 65535 strokes. If this maximum capacity is exceeded the pump will register a fault.
ProMinent® | Page 49 |