Dulcodes | Troubleshooting / Decommissioning and disposal | |
|
| |
| Red LED display is lit, ÒErrorÓ appears in the display and ÒFANÓ is flashing | |
Cause | Fault related to fan in pump housing. | |
Remedy | Check fan and replace if necessary. | |
| Press the P key (reset function). | |
| Red LED display is lit, ÒErrorÓ appears in the display and ÒSYSTEMÓ is flashing | |
Cause | Controller fault. | |
Remedy | Disconnect the pump from the mains and reconnect. | |
| If the error message continues, send the pump back to ProMinent. | |
| Red LED lights up, ÒErrorÓ appears in the display and ÒMenuÓ flashes. | |
Cause | Stroke buffer full | |
Remedy | Rectify fault | |
| Press P key (Make a note of what effect this has on your process). | |
| All other Errors | |
| Please contact your ProMinent branch or representative! | |
| Fault Signals | |
| Yellow LED display is lit | |
Cause | Liquid level in chemical storage tank has reached “liquid level low, stage 1”. | |
Remedy | Fill chemical storage tank. | |
| Yellow LED Display is lit and ÒcalibÓ flashes | |
Cause | The pump is calibrated and the stroke length deviates by more than ±10 % from the value at | |
| the time of calibration. | |
Remedy | Reset the stroke length or calibrate the pump again to the desired stroke length. | |
| 10 | Decommissioning and disposal |
Decommissioning |
|
|
| WARNING |
|
¥
¥ For all metering pumps for metering inflammable media applies: Starting up and emptying only supervised by a competent person.
¥ When decommissioning the pump, ensure that all dirt and chemicals are cleaned from the housing and particularly the liquid end.
¥ Always take suitable precautions when using hazardous chemicals! ¥ Ensure that the equipment is
Disconnect the pump from the mains.
Empty the liquid end by placing the pump on its head and allowing the chemical to drain out.
Rinse the liquid end with a suitable material, thoroughly rinse the liquid end after use with hazardous materials!
If decommissioning is only temporary, maintain the correct storage conditions:
Storage temperature:
Air humidity: | < 92 % relative humidity |
Disposal
WARNING
Spring under tension!
Take particular care when disassembling the pump as the return spring (Item 5, Chapter 2.2) is under considerable mechanical tension!
IMPORTANT
Observe your locally applicable regulations (particularly with regard to electronic scrap and gear oil)!
ProMinent® | Page 55 |