Operating Instructions
Control elements overview
Control elements and key functions
Continuous Display
Operating-/Settings Diagram
Previous
Activatedfunction
Analog
Imprint
Imprint Dulcodes UV-Desinfektionsanlage
Dulcodes UV-Desinfektionsanlage Table of contents
Table of contents Dulcodes UV-Desinfektionsanlage
B a G m a B a s i c Ty p e S 2 B a
Identcode ordering system
Identcode ordering system Dulcodes UV-Desinfektionsanlage
ProMinent
Dulcodes UV-Desinfektionsanlage
General notes
Safety devices
Dulcodes UV-Desinfektionsanlage
Identification of pump type
Product description S2Ba/S2Ca
Design/Functional description Functional description, drive
75 % 30 %
Stroke movement
HM50Hz MeteringcapacitydiagramS2Ba
Metering capacity diagram
S2CaHM
Functional description, delivery unit
Task
Integrated overflow valve with bleeder function
Design and functional description refer to Fig. No
Product description S2Ba/S2Ca
Design and function description see Fig
Diaphragm rupture sensor
Use for intended purpose/Use unintended purpose
Function
3162-4
Pvdf Ptfe
Technical data Sigma Capacity data
Technical data
Temperature specifications
Technical data S2Ca
Accuracy
Dimension sheet Sigma/ 2 with stroke adjustment motor
Dimensions Sigma/ 2 mm
Model Connector
Electrical data, stroke sensor ÒSigmaÓ
Stroke adjuster drive mechanism
Motor data
Stroke actuator drive mechanism
Relay input
Input voltage Mains frequency Power consumption
Electrical data, pacing relay ÒSigmaÓ
Sound intensity level
Maintenance
Start-up/Maintenance
Start-up
Maintenance intervals
Replacement of wearing parts
Guideline on Valve Installation
Function description, motors
Features of the S2Ca metering pumps
Function description, controller
LED indicator Operating indicator green
ÒFloat switchÓ function
Optional Òfault-indicating relayÓ or Òpower relayÓ
ÒFault indicating and pacing relayÓ option
Hierarchy of operating modes, functions and fault statuses
Sockets, symbols and wiring diagram
Relay type Power relay
Wiring diagram
Controller type 0 see identity code
Technical data, external contact
Controller type 1 see identity code
Outputs
Block circuit diagram S2Ca
Inputs
Pump, Inside
By customer Cable
Circuit examples universal signal cable
Not in Profibus version Delivery range
Retrofitting relays
Control elements
Set
Settings
Change to settings mode
Check adjustable values
Select operating mode Mode menu
Settings for ÒmanualÓ operating mode
Settings for operating mode SET menu
Settings for ÒanalogueÓ operating mode Analg menu
Straight line
Set
Lower band
Settings for ÒcontactÓ operating mode Contct menu
Lower/upper band
Lower band Upper band Alkali pump Acid pump
Set
ÒMemoryÓ extension function
Settings for ÒbatchÓ operating mode Batch menu
Settings for ÒcalibrationÓ function Calib menu
Settings for programmable functions SET menu
Cancel total stroke number or total litres Clear window
Settings for Òauxiliary frequencyÓ function AUX menu
Settings for the ÒflowÓ function Flow menu
Setting code Code menu
Manual operation
Operating
Remote control
Troubleshooting
Error Messages
Decommissioning and disposal
Spare parts and accessories
1011036
ProMinent
For pumps without Ex protection For pumps with Ex protection
Valve assy DN 15/PVT* Order No
6105-1040100-03
Order No
Retrofit kit double diaphragm S2Ba/S2Ca
Wiring diagram for stroke length adjuster
Stroke actuator wiring diagram