Dulcodes UV-Desinfektionsanlage

Features of the S2Ca metering pumps

 

 

Wiring diagram

View of cable connectors from front

Float switch cable

for

blue/alarm

blackGND

brownpause

2

1

3

Blue and black open -> alarm signal Brown and black open

-> alarm signal + pump stops

Metering monitor cable

for

brown/5V

white/cod

blue

black/GND

1

2

3

4

Diaphragm rupture cable

for

blue/alarm

black/GND

2

1

Contact open

-> alarm

 

-> pump stops with controller type 0

Universal signal cable (5-core)

for

brown/pause

white/cod

blue/analogue

black/GND

grey/auxiliary

1

2

3

4

5

Pause function:

brown and black closed -> pump metering

brown and black open

-> alarm + pump stopped

External/contact:

white and black closed

-> start contact for pump (note pause function: brown and black closed?)

Analogue:

blue, black

-> analogue output 0/4-20 mA (note pause function:

brown and black closed?)

Auxiliary frequency:

grey and black closed

-> pump metering at pre-set stroking rate

Circuit examples see p. 40

External/contact cable (2 core)

for

2brown

4white

Contact closed -> metering stroke

ProMinent®

Page 37

Page 37
Image 37
Sigma S2Ca, S2Ba warranty Wiring diagram