Settings

Dulcodes UV-Desinfektionsanlage

 

 

4 - 20 mA: at 4 mA the S2Ca does not operate

 

 

at 20 mA the S2Ca operates at 180 strokes/min.

 

 

 

 

 

Between these two extremes the stroke rate is proportional to the electrical

 

 

signal.

 

 

 

 

 

 

 

 

 

 

For signals of below 3.8 mA a fault will be detected and the S2Ca will stop

 

 

(e.g. cable break).

 

 

 

 

 

 

Curve:

In the “curve” processing mode you can programme the S2Ca ratios.

 

 

￿￿￿

There are 3 options available:

 

 

 

 

 

 

=

straight line

 

 

 

 

 

 

 

=

lower band

 

 

 

 

 

 

 

=

upper band

 

 

 

 

 

 

 

P

 

￿

P

Analog

￿

P

Analog

P

 

Set ￿￿

Set

￿￿

Set

 

 

 

Analog

 

P

Analog

￿￿Freq.

P

Analog

P

 

 

 

 

mA

 

Set

 

 

 

mA

 

 

 

Set ￿￿￿￿

 

 

 

Set ￿￿￿￿￿

 

Analog

Freq.

Set

Continuous

display

Straight line:

P

Analog

Set ￿

P

The following symbol appears in the LCD display: .

You can enter any stroke frequency ratio for the S2Ca in proportion to the electrical signal. You must enter two points P1 (I1, F1) and P2 (I2, F2). F1 is the stroke rate at which the pump should operate at current I1: the straight line and the ratio are fixed accordingly:

Fmax

F2

F1

P2

P1

0

I 1

I 2

20 I [mA]

Fig. 19

NOTE

Draw a diagram like the one above - with values for (I1, F1) and (I2, F2) - in order to set the S2Ca to your required stroke rate!

Page 46

ProMinent®

Page 46
Image 46
Sigma S2Ba, S2Ca warranty Set, Straight line