Settings

Dulcodes UV-Desinfektionsanlage

 

 

In the “contact - identity code: external with external pulse control” you can enter the number

of pulses after which a stroke should be carried out. “Contact - identity code: external with external pulse control” is intended for small dosing quantities.

￿￿￿

Continuous display

P

Set ￿￿￿￿￿

P

Contact

Set ￿￿

 

 

Mem

P

￿￿￿Contact￿

Mem

Set

P

The number of strokes per pulse depends upon the factor, which you can enter. This allows you to vary to a certain extent the input pulses by a factor of 1.01 to 99.99 and/or reduce by a factor of 0.01 to 0.99:

“Number of strokes activated = factor x number of input pulses”

Examples

Factor

Pulse (sequential)

Stroke number (sequential)

 

Increase

1

1

1

 

 

2

1

2

 

 

 

 

 

 

 

25

1

25

 

 

99.99

1

99.99

 

 

 

 

 

 

 

1.50

1

1.5 (1 / 2)

 

 

1.25

1

1.25 (1 / 1 / 1 / 2)

 

 

 

 

 

 

Reduction

1

1

1

 

 

0.50

2

1

 

 

 

 

 

 

 

0.10

10

1

 

 

0.01

100

1

 

 

 

 

 

 

 

0.25

4

1

 

 

0.40

2.5 (3 / 2)

(1 / 1)

 

 

 

 

 

 

 

0.75

1.33 (2 / 1 / 1)

(1 / 1 / 1)

 

 

 

 

 

Explanation of increase

At a factor of

1

For every 1 pulse, 1 stroke is activated

 

At a factor of

2

For every 1 pulse, 2 strokes are activated

 

At a factor of

25

For every 1 pulse, 25 strokes are activated

Explanation of decrease

At a factor of 1

After 1 pulse, 1 stroke is activated

 

At a factor of 0.5

After 2 pulses, 1 stroke is activated

 

At a factor of 0.1

After 10 pulses, 1 stroke is activated

 

At a factor of 0.75

After 2 pulses, 1 stroke is activated,

 

 

 

then after 1 pulse, 1 stroke is activated,

 

 

 

then after 2 pulses, 1 stroke is activated etc.