Control elements and key functions

Control elements: overview

4

3

2

1

5

16

6 7 8

9

10

15

14 13 12

11

1Operating light (green)

2 Warning light (yellow)

3 Error warning light (red)

4 Stroke length adjuster

5 LCD display

6 UP key

7 DOWN key

8 P key

9 STOP/START key

10i key

11Relay output (optional)

12Metering monitor socket

13Float switch socket

14External control socket

15Diaphragm rupture indicator socket

16Mains switch

Key functions

 

 

In continuous display mode

In settings mode

 

 

(operating)

(settings)

 

 

 

STOP/START key

 

 

STOP

 

 

 

START

 

 

 

Press briefly

Stop pump,

Stop pump,

 

 

start pump

start pump

 

 

 

 

P key

 

 

 

P

 

 

 

Press briefly

Start batch (in “batch” operating mode only),

Confirm entry- jump to next menu

 

 

Cancel error

option or continuous display

Press for

2 s

Change to settings mode

---

Press for

3 s

---

Jump to continuous display

Press for 10 s

Software version displayed

 

Press for 15 s

Load factory settings (calibration)

---

 

 

 

 

i key

 

 

 

i

 

 

 

Press x1

 

Toggle between continuous displays

Toggle between “change individual digits”

 

 

 

and change a figure"

Press x2

 

---

For “change individual digits”:

 

 

 

jumps to first digit

 

 

 

Arrow keys UP and DOWN

 

 

Press separately

Change directly alterable values

Select other settings,

(until “Set” appears)

 

change individual digit or figure

Press simultaneously

Prime (in “stroke rate” permanent display)

---

Page 2
Image 2
Sigma S2Ba, S2Ca warranty Control elements and key functions, Control elements overview