Technical dataDulcodes UV-Desinfektionsanlage

 

 

3.1.4

Motor data

 

 

 

 

 

Electrical Data

 

 

 

Motors:

 

 

 

 

 

Identcode characteristic

 

 

 

 

 

 

 

3 ph IP 55

230

V/400 V

50 Hz

0.25 kW

1.62/0.94 A

S

3 ph IP 55

230

V/400 V

60 Hz

0.25 kW

1.42/0.82 A

S

 

 

 

 

 

 

 

1 ph AC

230

V

50/60 Hz

0.18 kW

1.7/1.5 A

M

1 ph AC

115 V

60 Hz

0.18 kW

3.3 A

N

 

 

 

 

 

 

 

3 ph EXe or EXde

230

V/400 V

50 Hz

0.18 kW

1.1/0.7 A

L

3 ph EXe or EXde

230

V/400 V

60 Hz

0.18 kW

1.1/0.6 A

P

 

 

 

 

 

 

 

3 ph IP 55

230

V/400 V

50/60 Hz

0.37 kW

......

R Version with external fan

 

 

 

 

 

 

1 PH 230 v; 50/60 Hz and PTC

1 ph IP 55

230

V

50/60 Hz

0.37 kW

.....

V Three phase motor with integrated

 

 

 

 

 

 

speed changer, (see chapter 11)

direction of rotation

Fig. 11

For more details you can request the motor specification sheets. Custom motors and/or custom motor flanges are available on request.

WARNING

¥EX-pump only: Drive motors must be secured by an appropriate motor protection switch. A motor protection approved for this application must be used for ExÒeÓ-motors. (Protection against heating due to overload)

¥EX-pump only: motors in EX-areas must be installed and checked by persons with Òrecognised skillsÓ!

¥EX-pump only: observe the operating manual supplied with the EX motor!

Fuse data

IMPORTANT

¥The motors are not fuse-protected. Fit a motor circuit breaker!

¥When connecting the motor, make sure that it rotates in the correct direction (see Fig. 11). Protection against accidental contact and moisture (IP)

Motor: IP 55 DIN EN 60034-5 (in accordance with DIN VDE 0470 Part 1, corresponds to EN 60529 and IEC 529).

External fan

Notes on the speed-controlled motor with separate fan and temperature monitoring may be found in the “General Operating Instructions ProMinent® Motor-Driven Metering Pumps and Hydraulic Accessories”.

3.1.5Stroke actuator drive mechanism

230 V ± 10 %

50/60 Hz

11.7 W

 

 

 

115 V ± 10 %

60 Hz

11.7 W

 

 

 

Cf. “Appendix” for terminal connection diagram.

3.1.6Stroke adjuster drive mechanism

230 V ± 10 %

50/60 Hz

6.5 W

 

 

 

115 V ± 10 %

60 Hz

6.5 W

 

 

 

Cf. “Appendix” for terminal connection diagram.

3.1.7Electrical data, stroke sensor ÒSigmaÓ

a)Reed contact (Identcode characteristic ÒStroke sensorÓ: 1)

Pin 1

(white)

=

4.5 V to 24 V, max. 10 mA

Pin 2

(brown)

=

OUT, open collector, 24 V, 20 mA

Pin 3

(green)

=

GND

Pulse width (low)

4 ms (depending on gearbox and power frequency)

Page 28

ProMinent®

Page 28
Image 28