Technical dataDulcodes
|
| 3.1.4 | Motor data |
|
|
|
|
| Electrical Data |
|
|
| |
Motors: |
|
|
|
|
| Identcode characteristic |
|
|
|
|
|
|
|
3 ph IP 55 | 230 | V/400 V | 50 Hz | 0.25 kW | 1.62/0.94 A | S |
3 ph IP 55 | 230 | V/400 V | 60 Hz | 0.25 kW | 1.42/0.82 A | S |
|
|
|
|
|
|
|
1 ph AC | 230 | V | 50/60 Hz | 0.18 kW | 1.7/1.5 A | M |
1 ph AC | 115 V | 60 Hz | 0.18 kW | 3.3 A | N | |
|
|
|
|
|
|
|
3 ph EXe or EXde | 230 | V/400 V | 50 Hz | 0.18 kW | 1.1/0.7 A | L |
3 ph EXe or EXde | 230 | V/400 V | 60 Hz | 0.18 kW | 1.1/0.6 A | P |
|
|
|
|
|
|
|
3 ph IP 55 | 230 | V/400 V | 50/60 Hz | 0.37 kW | ...... | R Version with external fan |
|
|
|
|
|
| 1 PH 230 v; 50/60 Hz and PTC |
1 ph IP 55 | 230 | V | 50/60 Hz | 0.37 kW | ..... | V Three phase motor with integrated |
|
|
|
|
|
| speed changer, (see chapter 11) |
direction of rotation
Fig. 11
For more details you can request the motor specification sheets. Custom motors and/or custom motor flanges are available on request.
WARNING
¥
¥
¥
Fuse data
IMPORTANT
¥The motors are not
¥When connecting the motor, make sure that it rotates in the correct direction (see Fig. 11). Protection against accidental contact and moisture (IP)
Motor: IP 55 DIN EN
External fan
Notes on the
3.1.5Stroke actuator drive mechanism
230 V ± 10 % | 50/60 Hz | 11.7 W |
|
|
|
115 V ± 10 % | 60 Hz | 11.7 W |
|
|
|
Cf. “Appendix” for terminal connection diagram.
3.1.6Stroke adjuster drive mechanism
230 V ± 10 % | 50/60 Hz | 6.5 W |
|
|
|
115 V ± 10 % | 60 Hz | 6.5 W |
|
|
|
Cf. “Appendix” for terminal connection diagram.
3.1.7Electrical data, stroke sensor ÒSigmaÓ
a)Reed contact (Identcode characteristic ÒStroke sensorÓ: 1)
Pin 1 | (white) | = | 4.5 V to 24 V, max. 10 mA |
Pin 2 | (brown) | = | OUT, open collector, 24 V, 20 mA |
Pin 3 | (green) | = | GND |
Pulse width (low) ≥ | 4 ms (depending on gearbox and power frequency) |
Page 28 | ProMinent® |