Dulcodes | Identcode ordering system |
|
|
Identcode ordering system
Please enter the identcode on the device label into the grey box below.
S 2 B a
S i g m a B a s i c Ty p e ( S 2 B a )
HM | Main drive, diaphragm | ||
|
|
| |
|
| Pump type: (figures 1+2 = back pressure [bar], figures | |
| 16050 | 16 bar; | 50 l/h |
| 16090 | 16 bar; | 90 l/h |
| 16130 | 16 bar; 130 l/h | |
| 12050* | 10 bar; | 48 l/h |
| 12090* | 10 bar; | 86 l/h |
| 12030* | 10 bar; 125 l/h | |
| 07120 | 7 bar; 120 l/h | |
| 07220 | 7 bar; 220 l/h | |
| 04350 | 4 bar; 350 l/h * for SST versions, max. 12 bar | |
|
|
|
|
| Liquid end materials: |
PV | PVDF |
SS | Stainless steel |
Seal material:
TPTFE seal
Diaphragm:
0Standard diaphragm, PTFE version
1Double diaphragm with diaphragm rupture indicator (retro fit possible)
Liquid end version:
0No spring
1With 2 valve springs, Hastelloy C, 0.1 bar
4With pressure relief valve, Viton® seal, no valve spring
5 With pressure relief valve, Viton® seal, and valve spring
Hydraulic connection:
0Standard threaded connector (according to technical data)
1 Union nut and PVC insert
2 Union nut and PP insert
3 Union nut and PVDF insert
4 Union nut and stainless steel insert
7 Union nut and PVDF hose nozzle
8 Union nut and stainless steel hose nozzle
Version:
0With ProMinent® logo (standard)
1 Without ProMinent® logo
Electrical power supply:
S3 ph, 230 V/400 V 50/60 Hz, 0.18 kW M 1 ph, AC, 230 V/50/60 Hz, 0.18 kW
N 1 ph, AC 115 V 60 Hz, 0.18 kW
L 3 ph, 230 V/400 V, 50 Hz, (EExe, EExde)
P 3 ph, 230 V/400 V, 60 Hz, (EExe, EExde)
R 3 ph, variable speed motor, 230/400 V, 0.37 kW
V Variable speed motor with integrated speed control 1 pH, 230 V, 50/60 Hz
Z 1 ph, variable speed control set 1 ph, 230 V, 50/60 Hz
1 No motor, with B14 flange (Gr. 71 (DIN))
2 No motor, C 56 flange (NEMA)
3 No motor, B5 Gr. 63 (DIN)
4 No motor, B5, Gr. 70 (DIN)
Motor version:
0IP 55 (standard)
1Exe version (II 2G EExe II T3)
2Exde version (II 2G EExde IIC T4)
A ATEX type drive
| Stroke sensor: |
0 | No stroke sensor (standard) |
1 | with stroke sensor (Hall sensor, no connection cable) |
2 | Pacing relay (reed relay) |
3 | Stroke sensor (Namur) intrinsically safe |
|
|
|
| Stroke length adjustment: |
| 0 | Manual (standard) | ||
| 1 | With stroke positioning motor, 230 V/50/60 Hz | ||
| 2 | With stroke positioning motor, 115 V/50/60 Hz | ||
| 3 | With stroke control motor, | ||
|
|
|
| 0...20 mA 230 V/50/60 Hz |
| 4 | With stroke control motor | ||
|
|
|
| 4...20 mA 230 V/50/60 Hz |
| 5 | With stroke control motor | ||
|
|
|
| 0...20 mA 115 V/50/60 Hz |
| 6 | With stroke control motor | ||
|
|
|
| 4...20 mA 115 V/50/60 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S2Ba | ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ |
|
|
Viton® is a registered trademark of DuPont Dow Elastomers.
® | ® | Page 9 |
ProMinentProMinent |