7.1Check adjustable values

Before setting up the S2Ca you can check the current settings of adjustable values:

Press the i key (“i” as in “info”) when the S2Ca is in continuous display mode (There is no P key symbol in the LCD display).

Each time you press the i key you will see a different continuous display. The number of continuous displays depends upon the identity code, the selected operating mode and the connected accessories (see overview “continuous displays”).

7.2Change to settings mode

If you hold down the P key for 2 seconds in any continuous display, the S2Ca will change to the settings mode.

If CODE 1 is set, the code must be entered after pressing the P key.

The following menu options appear first in the settings mode (see also overview “operating/ settings diagram”):

MODE menu

CODE menu (optional)

SET menu

CLEAR window

In order to adapt the S2Ca to your process requirements you must:

1.Select the operating mode in the MODE menu.

2.If necessary enter the settings for this operating mode in the SET menu. Exception: Timer and PROFIBUS®.

IMPORTANT

Note the diagram below!

 

 

1.

 

 

MODE

 

 

menu

 

 

CODE

 

 

menu

Continuous

2 s

 

P

 

display

2.

 

 

 

SET

 

 

menu

 

 

CLEAR

 

 

window

7.3Select operating mode (MODE menu)

The following operating modes are selected via the MODE menu (depending upon identity code, some operating modes may be absent):

Manual: for operation by hand

(Identity code, control variant: manual, standard option)

Analogue: for electronic control

(Identity code, control variant: analogue current)

Page 44