4.5.2.3 Timer/counter 0 and 1 count clock designation

Designation of count clock inputs to timer/counters 0 and 1 is controlled by bit 2 and 6, C/T, in the timer mode register (TMOD 89H).

Timer/counter 0 is controlled by bit 2, C/T, and timer/counter 1 is controlled by bit 6, C/T. The internal clock is passed to the timer/counter when the C/T bit is “0”. This internal clock is the result of dividing XTAL1·2 by 12. The S3 timing signal (see Figure 2-9) becomes the clock.

The external clock is applied to the timer/counter when the C/T bit is “1”. The external clock applied to the T0 pin serves as the timer/counter 0 input, while the external clock applied to the T1 pin serves as the timer/counter 1 input.

Table 4-8 Timer mode register (TMOD 89H)

 

 

Timer 1

 

 

Timer 0

 

 

 

 

 

 

 

 

 

 

Bit

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

Flag

GATE

C/T

M1

M0

GATE

C/T

M1

M0

 

 

 

 

 

 

 

 

 