Menu List

Item number

Item

Settable range

Function

120

WARNING

[off]

Selects whether warning messages should be displayed in

 

DISPLAY

on

the lower part of the timecode display for the HOME menu,

 

 

 

the TC menu, the PF1 menu, and the PF2 menu.

 

 

 

off: Do not display warning messages.

 

 

 

on:Displaywarningmessages.

 

 

Notes

 

 

 

• No warning messages are displayed for the CUE menu, so

 

 

check by viewing a menu other than the CUE menu.

 

 

• If LOST LOCK occurs during playback or recording, a

 

 

LOST LOCK warning message is always displayed.

121

INFORMATION

Selects items to be displayed in the operation information.

 

DISPLAY

 

 

 

 

Sub items

 

 

 

 

SYSTEM

[off]

off: Does not display the field frequency of both the unit and

 

 

FREQUENCY

diff

the tape.

 

 

 

ever

diff: Displays the field frequency of the unit and the tape only

 

 

 

 

when they do not match.

 

 

 

 

ever: Always displays the field frequency of the unit and the

 

 

 

 

tape.

 

 

 

 

 

 

 

ACTIVE LINE (HD)

[off]

off: Does not display the effective scanning line number to

 

 

 

diff

be input or played back, and to be output.

 

 

 

ever

diff: Displays the effective scanning line number to be input

 

 

 

 

and to output only when they do not match.

 

 

 

 

ever: Always displays the effective scanning line number to

 

 

 

 

be input and output.

 

 

EOS DISPLAY

[off]

off: Does not display EOS.

 

 

 

on

on: Displays EOS.

 

 

 

 

 

 

 

VIDEO INT SG

[off]

off: Does not display the type of the test signal generated by

 

 

 

on

the internal video test signal generator.

 

 

 

 

on: Display the type of the test signal generated by the

 

 

 

 

internalvideotestsignalgenerator.

 

 

 

 

 

 

 

AUDIO INT SG

[off]

off: Does not display the operating status of the internal

 

 

 

on

audiotestsignalgenerator.

 

 

 

 

on: Displays the operating status of the internal audio test

 

 

 

 

signalgenerator.

 

 

 

 

 

 

 

META DATA

[off]

Selects whether the reception setting (bank name) for the

Appendix

 

on

meta data multiplexed in the HD SDI packet is displayed or

 

 

not.

 

 

 

 

 

 

 

 

off: The bank name is not displayed.

 

 

 

 

on: The bank name is displayed.

122

MULTI CUE

[on]

Selects whether to erase cue point data in multi-cue mode

 

 

CLEAR by inject

off

when a cassette is inserted.

 

 

 

 

on : Erase cue point data.

 

 

 

 

off : Do not erase cue point data.

123

Tele-File

[control panel]

Selects the device to be used for TELE FILE menu

 

 

CONTROL MODE

RS-232C

operations.

 

 

 

 

control panel: The control panel of the VTR is used.

 

 

 

 

RS-232C: A personal computer connected to the RS-232C

 

 

 

 

connector of the VTR is used.

124

Tele-File MENU

[off]

Specifies whether or not the TELE FILE menu appears

 

 

autopopup

on

automatically when a cassette with a memory label is

 

 

 

 

inserted.

 

 

 

 

off: The TELE FILE menu does not appear.

 

 

 

 

on: The TELE FILE menu appears.

 

125

Tele-File THREAD

[not clear]

Specifies whether or not the thread counter is reset when a

 

 

COUNTER clear

whenformat

memory label is formatted.

 

 

mode

 

not clear: The thread counter is not reset.

 

 

 

 

when format: The thread counter is reset.

A-22Appendix

Page 168
Image 168
Sony HKDV-503, 507D Information, System, Frequency, Active Line HD, EOS Display, Video INT SG, Audio INT SG, Meta Data