Item number

Item

Settable range

Function

627

CHAR WARNING

[off]

When item 626 is set to anything other than time data only,

 

DISPLAY at dual

on

this item specifies whether warning messages flash on the

 

line mode

 

second line or not.

 

 

 

off: Warning messages do not flash.

 

 

 

on: If a warning message exists, it flashes.

 

 

 

Notes

 

 

 

 

• Messages that have been cleared are not displayed. For

 

 

 

more information about clearing warning messages, see

 

 

 

“Clearing warning messages” on page A-12.

 

 

 

• When there are multiple warning messages, each

 

 

 

message flashes twice before it is replaced by the next

 

 

 

message.

 

 

 

 

628

REMAIN TIME

[off]

Sets whether to display remaining time on the tape in

 

DISPLAY

10min

superimposed charecter position.

 

 

on

off: Do not display remaining time.

 

 

 

10 min: Display remaining time when it is 10 minutes or

 

 

 

less.

 

 

 

on: Always display remaining time.

 

 

 

Notes

 

 

 

 

The remaining time on the tape is not displayed when no

 

 

 

cassette is inserted. The remaining time is not also

 

 

 

displayed until the VTR finishes detecting the diameter of

 

 

 

the wound tape and estimating the remaining time

 

 

 

immediately after the cassette is inserted.

 

 

 

 

630

TC CONVERSION

[off]

Specifies whether or not to convert the 24 frames time code

 

at 25F off-speed

on

to the 25 frames time code when off-speed playing back the

 

PB

 

cassette tape recorded in the 24F mode with the 25F mode.

 

 

 

off: Does not convert the 24 frames time code to the 25

 

 

 

frames time code.

 

 

 

on: Converts the 24 frames time code to the 25 frames time

 

 

 

code.

 

 

 

 

 

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This setting is only active when the field frequency is 25 Hz.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

631

ORIGINAL TC

[off]

When item 630 is set to “on,” this setting specifies whether

Appendix

 

display

on

the 24-frame time code is displayed or not on the control

 

 

 

 

panel of the VTR before conversion.

 

 

 

 

 

 

 

 

off: The 24-frame time code is not displayed before

 

 

 

 

 

conversion.

 

 

 

 

on: The 24-frame time code is displayed before conversion.

 

 

 

 

 

The type of time code type displayed is specified by item

 

 

 

 

603.

 

 

 

 

 

 

 

 

632

JUMPING TC

[–3H]

When the 24-frame time code is converted to 25-frame time

 

 

select

–2H

code, this setting specifies the loopback point (JUMPING

 

 

 

TC) with respect to the reference point for conversion

 

 

 

–1H

 

 

 

(STARTING TC).

 

 

 

+1H

–3H: The JUMPING TC is set 3 hours before STARTING

 

 

 

+2H

 

TC.

 

 

 

–2H: The JUMPING TC is set 2 hours before STARTING

 

 

 

+3H

 

 

 

 

TC.

 

 

 

0H

–1H: The JUMPING TC is set 1 hour before STARTING TC.

 

 

 

+1H: The JUMPING TC is set 1 hour after STARTING TC.

 

 

 

 

 

 

 

 

+2H: The JUMPING TC is set 2 hours after STARTING TC.

 

 

 

 

+3H: The JUMPING TC is set 3 hours after STARTING TC.

 

 

 

 

0H: The JUMPING TC is set 1 frame before STARTING TC.

 

Appendix A-33